Cited 8 time in
Evaluation of glomerular filtration rate by use of dynamic computed tomography and Patlak analysis in clinically normal cats
| DC Field | Value | Language |
|---|---|---|
| dc.contributor.author | Chang, Jinhwa | - |
| dc.contributor.author | Ahn, Sejoon | - |
| dc.contributor.author | Choi, Sooyoung | - |
| dc.contributor.author | Lee, Heechun | - |
| dc.contributor.author | Chang, Dongwoo | - |
| dc.contributor.author | Choi, Hojung | - |
| dc.contributor.author | Lee, Youngwon | - |
| dc.date.accessioned | 2022-12-27T02:54:38Z | - |
| dc.date.available | 2022-12-27T02:54:38Z | - |
| dc.date.issued | 2011-09 | - |
| dc.identifier.issn | 0002-9645 | - |
| dc.identifier.issn | 1943-5681 | - |
| dc.identifier.uri | https://scholarworks.gnu.ac.kr/handle/sw.gnu/23584 | - |
| dc.description.abstract | Objective-To obtain quantitative variables of the abdominal aorta and both kidneys on the basis of time-attenuation curves (TACs) and to measure glomerular filtration rate (GFR) for each kidney and the global GFR in clinically normal cats by use of dynamic computed tomography (CT) and Patlak analysis. Animals-9 healthy cats. Procedures-All the cats were anesthetized with propofol. Anesthesia was maintained by administration of isoflurane, and CT examination was performed in the anesthetized cats. The TACs and renal volume were measured by use of the baseline precontrast and single-slice dynamic scans. The CT-GFR of each kidney and the global CT-GFRs were calculated via Patlak plot analysis. Results-CT-GFR results from 7 cats were valid. Peak aortic enhancement was detected between 9.0 and 14.0 seconds after iohexol injection, and the initial peak time of renal parenchymal enhancement was 15 to 24 seconds after iohexol injection. Mean +/- SD global GFR was 2.06 +/- 0.62 mL/min/kg. Mean +/- SD CT-GFR of the right and left kidneys was 0.97 +/- 0.32 mL/min/kg and 1.05 +/- 0.31 mL/min/kg, respectively. Conclusions and Clinical Relevance-The CT-GFR method can be rapidly and conveniently performed in clinically normal cats. This combined structural-functional approach provided physiologic and morphological information on the kidneys of cats. (Am J Vet Res 201172:1276-1282) | - |
| dc.format.extent | 7 | - |
| dc.language | 영어 | - |
| dc.language.iso | ENG | - |
| dc.publisher | AMER VETERINARY MEDICAL ASSOC | - |
| dc.title | Evaluation of glomerular filtration rate by use of dynamic computed tomography and Patlak analysis in clinically normal cats | - |
| dc.type | Article | - |
| dc.publisher.location | 미국 | - |
| dc.identifier.doi | 10.2460/ajvr.72.9.1276 | - |
| dc.identifier.scopusid | 2-s2.0-80052510141 | - |
| dc.identifier.wosid | 000294510000018 | - |
| dc.identifier.bibliographicCitation | AMERICAN JOURNAL OF VETERINARY RESEARCH, v.72, no.9, pp 1276 - 1282 | - |
| dc.citation.title | AMERICAN JOURNAL OF VETERINARY RESEARCH | - |
| dc.citation.volume | 72 | - |
| dc.citation.number | 9 | - |
| dc.citation.startPage | 1276 | - |
| dc.citation.endPage | 1282 | - |
| dc.type.docType | Article | - |
| dc.description.isOpenAccess | N | - |
| dc.description.journalRegisteredClass | sci | - |
| dc.description.journalRegisteredClass | scie | - |
| dc.description.journalRegisteredClass | scopus | - |
| dc.relation.journalResearchArea | Veterinary Sciences | - |
| dc.relation.journalWebOfScienceCategory | Veterinary Sciences | - |
| dc.subject.keywordPlus | UNIT RENAL VOLUME | - |
| dc.subject.keywordPlus | TRANSFER CONSTANTS | - |
| dc.subject.keywordPlus | PLASMA-CLEARANCE | - |
| dc.subject.keywordPlus | CONTRAST-MEDIA | - |
| dc.subject.keywordPlus | BLOOD-FLOW | - |
| dc.subject.keywordPlus | HELICAL CT | - |
| dc.subject.keywordPlus | IOHEXOL | - |
| dc.subject.keywordPlus | DOGS | - |
Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.
Gyeongsang National University Central Library, 501, Jinju-daero, Jinju-si, Gyeongsangnam-do, 52828, Republic of Korea+82-55-772-0532
COPYRIGHT 2022 GYEONGSANG NATIONAL UNIVERSITY LIBRARY. ALL RIGHTS RESERVED.
Certain data included herein are derived from the © Web of Science of Clarivate Analytics. All rights reserved.
You may not copy or re-distribute this material in whole or in part without the prior written consent of Clarivate Analytics.
