Cited 14 time in
Inferolateral Entry Point for C2 Pedicle Screw Fixation in High Cervical Lesions
| DC Field | Value | Language |
|---|---|---|
| dc.contributor.author | Lee, Kwang Ho | - |
| dc.contributor.author | Kang, Dong Ho | - |
| dc.contributor.author | Lee, Chul Hee | - |
| dc.contributor.author | Hwang, Soo Hyun | - |
| dc.contributor.author | Park, In Sung | - |
| dc.contributor.author | Jung, Jin Myung | - |
| dc.date.accessioned | 2022-12-27T02:53:47Z | - |
| dc.date.available | 2022-12-27T02:53:47Z | - |
| dc.date.issued | 2011-10 | - |
| dc.identifier.issn | 2005-3711 | - |
| dc.identifier.issn | 1598-7876 | - |
| dc.identifier.uri | https://scholarworks.gnu.ac.kr/handle/sw.gnu/23557 | - |
| dc.description.abstract | Objective : The purpose of this retrospective study was to evaluate the efficacy and safety of atlantoaxial stabilization using a new entry point for C2 pedicle screw fixation. Methods : Data were collected from 44 patients undergoing posterior Cl lateral mass screw and C2 screw fixation. The 20 cases were approached by the Harms entry point, 21 by the inferolateral point, and three by pars screw. The new inferolateral entry point of the C2 pedicle was located about 3-5 mm medial to the lateral border of the C2 lateral mass and 5-7 mm superior to the inferior border of the C2-3 facet joint. The screw was inserted at an angle 30 to 450 toward the midline in the transverse plane and 40 to 50 cephalad in the sagittal plane. Patients received followed-up with clinical examinations, radiographs and/or CT scans. Results : There were 28 males and 16 females. No neurological deterioration or vertebral artery injuries were observed. Five cases showed malpositioned screws (2.84%), with four of the screws showing cortical breaches of the transverse foramen. There were no clinical consequences for these five patients. One screw in the Cl lateral mass had a medial cortical breach. None of the screws were malpositioned in patients treated using the new entry point. There was a significant relationship between two group (p=0.036). Conclusion : Posterior C1-2 screw fixation can be performed safely using the new inferolateral entry point for C2 pedicle screw fixation for the treatment of high cervical lesions. | - |
| dc.format.extent | 7 | - |
| dc.language | 영어 | - |
| dc.language.iso | ENG | - |
| dc.publisher | KOREAN NEUROSURGICAL SOC | - |
| dc.title | Inferolateral Entry Point for C2 Pedicle Screw Fixation in High Cervical Lesions | - |
| dc.type | Article | - |
| dc.publisher.location | 대한민국 | - |
| dc.identifier.doi | 10.3340/jkns.2011.50.4.341 | - |
| dc.identifier.scopusid | 2-s2.0-80655135529 | - |
| dc.identifier.wosid | 000296678000011 | - |
| dc.identifier.bibliographicCitation | JOURNAL OF KOREAN NEUROSURGICAL SOCIETY, v.50, no.4, pp 341 - 347 | - |
| dc.citation.title | JOURNAL OF KOREAN NEUROSURGICAL SOCIETY | - |
| dc.citation.volume | 50 | - |
| dc.citation.number | 4 | - |
| dc.citation.startPage | 341 | - |
| dc.citation.endPage | 347 | - |
| dc.type.docType | Article | - |
| dc.identifier.kciid | ART001599123 | - |
| dc.description.isOpenAccess | Y | - |
| dc.description.journalRegisteredClass | scie | - |
| dc.description.journalRegisteredClass | scopus | - |
| dc.description.journalRegisteredClass | kci | - |
| dc.relation.journalResearchArea | Neurosciences & Neurology | - |
| dc.relation.journalResearchArea | Surgery | - |
| dc.relation.journalWebOfScienceCategory | Clinical Neurology | - |
| dc.relation.journalWebOfScienceCategory | Surgery | - |
| dc.subject.keywordPlus | POSTERIOR ATLANTOAXIAL FIXATION | - |
| dc.subject.keywordPlus | VERTEBRAL ARTERY INJURY | - |
| dc.subject.keywordPlus | PLATE FIXATION | - |
| dc.subject.keywordPlus | LAMINAR SCREW | - |
| dc.subject.keywordPlus | STABILIZATION | - |
| dc.subject.keywordPlus | SUITABILITY | - |
| dc.subject.keywordPlus | PLACEMENT | - |
| dc.subject.keywordPlus | COMPLEX | - |
| dc.subject.keywordPlus | FUSION | - |
| dc.subject.keywordPlus | C1 | - |
| dc.subject.keywordAuthor | Atlantoaxial fixation | - |
| dc.subject.keywordAuthor | C2 pedicle screw | - |
| dc.subject.keywordAuthor | Entry point | - |
Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.
Gyeongsang National University Central Library, 501, Jinju-daero, Jinju-si, Gyeongsangnam-do, 52828, Republic of Korea+82-55-772-0532
COPYRIGHT 2022 GYEONGSANG NATIONAL UNIVERSITY LIBRARY. ALL RIGHTS RESERVED.
Certain data included herein are derived from the © Web of Science of Clarivate Analytics. All rights reserved.
You may not copy or re-distribute this material in whole or in part without the prior written consent of Clarivate Analytics.
