Cited 12 time in
Development and validation of an LC-ESI-MS/MS method for simultaneous determination of levodopa, dopamine, L-α-methyldopa and 3-O-methyldopa in rat plasma
| DC Field | Value | Language |
|---|---|---|
| dc.contributor.author | Cho, Y.A. | - |
| dc.contributor.author | Park, S. | - |
| dc.contributor.author | Seo, O.N. | - |
| dc.contributor.author | Jeong, S.W. | - |
| dc.contributor.author | Lee, W.-K. | - |
| dc.contributor.author | Kim, C.Y. | - |
| dc.contributor.author | Kim, S.T. | - |
| dc.contributor.author | Cho, M.J. | - |
| dc.contributor.author | Shin, S.C. | - |
| dc.date.accessioned | 2022-12-27T02:48:10Z | - |
| dc.date.available | 2022-12-27T02:48:10Z | - |
| dc.date.issued | 2012 | - |
| dc.identifier.issn | 2093-5552 | - |
| dc.identifier.issn | 2093-6214 | - |
| dc.identifier.uri | https://scholarworks.gnu.ac.kr/handle/sw.gnu/23353 | - |
| dc.description.abstract | Parkinson's disease (PD) is a progressive degenerative disorder of the central nervous system. Levodopa (L-dopa), dopamine precursor is the most effective therapeutic drug for PD patients. Levodopa (LDP) and its three metabolites in rat plasma were determined using high performance liquid chromatography coupled with tandem mass spectrometry (LC-MS/MS). Method validation was conducted in terms of linearity, accuracy, precision, recovery, specificity, limit of detection, limit of quantification and stability. Correlation coefficients (r2) were above 0. 9965. The intra-day accuracy values at LLOQ (low limit of quantification), LQC (low quality control), MQC (medium quality control) and HQC (high quality control) levels were 85. 7-103. 3, 96. 5-105. 1, 90. 7-100. 1 and 94. 2-101. 3 %, respectively. The inter-day accuracy values at LLOQ, LQC, MQC and HQC levels were 77. 6-112. 0, 91. 1-109. 3, 84. 3-101. 0 and 88. 2-103. 9 %, respectively. The coefficient of variation (RSD) values of both intra- and inter-day results were within 6. 7 and 8. 5 %, respectively. The recoveries (mean ± %SD) for LLOQ, LQC, MQC and HQC were 82. 7 ± 3. 7-113 ± 2. 8 %, 86. 6 ± 5. 7-110. 3±3. 4 %, 90. 9 ± 3. 6-106 ± 6. 5 and 89. 7 ± 4. 5-97. 4 ± 6. 7 %, respectively. The coefficient of variation (RSD) values of both intra- and inter-day results were within 6. 7 and 8. 5 %, respectively. The validated LC-MS/MS method was applied successfully to the measurement of LDP and its metabolites in the rat plasma samples. ? 2012 The Korean Society of Pharmaceutical Sciences and Technology. | - |
| dc.format.extent | 8 | - |
| dc.language | 영어 | - |
| dc.language.iso | ENG | - |
| dc.publisher | Kluwer Academic Publishers | - |
| dc.title | Development and validation of an LC-ESI-MS/MS method for simultaneous determination of levodopa, dopamine, L-α-methyldopa and 3-O-methyldopa in rat plasma | - |
| dc.type | Article | - |
| dc.publisher.location | 대한민국 | - |
| dc.identifier.doi | 10.1007/s40005-012-0048-x | - |
| dc.identifier.scopusid | 2-s2.0-84876573911 | - |
| dc.identifier.bibliographicCitation | Journal of Pharmaceutical Investigation, v.42, no.6, pp 361 - 368 | - |
| dc.citation.title | Journal of Pharmaceutical Investigation | - |
| dc.citation.volume | 42 | - |
| dc.citation.number | 6 | - |
| dc.citation.startPage | 361 | - |
| dc.citation.endPage | 368 | - |
| dc.type.docType | Article | - |
| dc.identifier.kciid | ART001719194 | - |
| dc.description.isOpenAccess | N | - |
| dc.description.journalRegisteredClass | scopus | - |
| dc.description.journalRegisteredClass | kci | - |
| dc.subject.keywordAuthor | Dopamine | - |
| dc.subject.keywordAuthor | LC-MS/MS | - |
| dc.subject.keywordAuthor | Levodopa | - |
| dc.subject.keywordAuthor | Parkinson's disease | - |
Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.
Gyeongsang National University Central Library, 501, Jinju-daero, Jinju-si, Gyeongsangnam-do, 52828, Republic of Korea+82-55-772-0532
COPYRIGHT 2022 GYEONGSANG NATIONAL UNIVERSITY LIBRARY. ALL RIGHTS RESERVED.
Certain data included herein are derived from the © Web of Science of Clarivate Analytics. All rights reserved.
You may not copy or re-distribute this material in whole or in part without the prior written consent of Clarivate Analytics.