Cited 4 time in
Automatic test method of sizing degree by analysis of liquid penetration and its surface behavior
| DC Field | Value | Language |
|---|---|---|
| dc.contributor.author | Lee, J.-Y. | - |
| dc.contributor.author | Kim, G.-C. | - |
| dc.contributor.author | Kim, C.-H. | - |
| dc.contributor.author | Sheikh, M.I. | - |
| dc.contributor.author | Park, H.-J. | - |
| dc.contributor.author | Kim, S.-H. | - |
| dc.contributor.author | Sim, S.-W. | - |
| dc.contributor.author | Cho, H.-S. | - |
| dc.date.accessioned | 2022-12-27T02:37:55Z | - |
| dc.date.available | 2022-12-27T02:37:55Z | - |
| dc.date.issued | 2012 | - |
| dc.identifier.issn | 0253-3200 | - |
| dc.identifier.uri | https://scholarworks.gnu.ac.kr/handle/sw.gnu/23242 | - |
| dc.description.abstract | This study was to develop a novel automatic system for measuring St?ckigt sizing degree and contact angle at a time. The conventional methods to measure sizing degree had serious problems in obtaining significant differences according to different dosages of a sizing agent, and moreover they disclosed unique limitation due to liquid types used and tester's subjectivity. However, the newly developed system could get reproducible results through total automation of all procedures including liquid dropping, image acquisition and measurement of both St?ckigt sizing degree and contact angle. For the St?ckigt sizing test, the automatic system could measure sizing degree with more definite differences according to different dosage of AKD, compared to the conventional method. For the contact angle test, the automatic system showed a similar trend to the conventional method but had smaller contact angles due to distortion of an image focus by a sheet curl than the conventional testing machine. The problem from the image out of focus due to specimen curl will be overcome with adopting a new specimen holder for the future system. | - |
| dc.format.extent | 11 | - |
| dc.language | 한국어 | - |
| dc.language.iso | KOR | - |
| dc.publisher | Korean Technical Assoc. of the Pulp and Paper Industry | - |
| dc.title | Automatic test method of sizing degree by analysis of liquid penetration and its surface behavior | - |
| dc.type | Article | - |
| dc.publisher.location | 대한민국 | - |
| dc.identifier.doi | 10.7584/ktappi.2012.44.2.018 | - |
| dc.identifier.scopusid | 2-s2.0-84861599534 | - |
| dc.identifier.bibliographicCitation | Palpu Chongi Gisul/Journal of Korea Technical Association of the Pulp and Paper Industry, v.44, no.2, pp 18 - 28 | - |
| dc.citation.title | Palpu Chongi Gisul/Journal of Korea Technical Association of the Pulp and Paper Industry | - |
| dc.citation.volume | 44 | - |
| dc.citation.number | 2 | - |
| dc.citation.startPage | 18 | - |
| dc.citation.endPage | 28 | - |
| dc.type.docType | Article | - |
| dc.identifier.kciid | ART001657419 | - |
| dc.description.isOpenAccess | Y | - |
| dc.description.journalRegisteredClass | scopus | - |
| dc.description.journalRegisteredClass | kci | - |
| dc.subject.keywordAuthor | Automatic system | - |
| dc.subject.keywordAuthor | Contact angle | - |
| dc.subject.keywordAuthor | Image acquisition | - |
| dc.subject.keywordAuthor | Sizing | - |
| dc.subject.keywordAuthor | Stockigt sizing test | - |
Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.
Gyeongsang National University Central Library, 501, Jinju-daero, Jinju-si, Gyeongsangnam-do, 52828, Republic of Korea+82-55-772-0532
COPYRIGHT 2022 GYEONGSANG NATIONAL UNIVERSITY LIBRARY. ALL RIGHTS RESERVED.
Certain data included herein are derived from the © Web of Science of Clarivate Analytics. All rights reserved.
You may not copy or re-distribute this material in whole or in part without the prior written consent of Clarivate Analytics.