Cited 0 time in
Implementation of Ceiling Fin to Prevent the Spread of Airborne Pathogens by Buoyancy Effect
| DC Field | Value | Language |
|---|---|---|
| dc.contributor.author | 정창헌 | - |
| dc.contributor.author | 황석호 | - |
| dc.contributor.author | 박병용 | - |
| dc.date.accessioned | 2022-12-26T09:20:24Z | - |
| dc.date.available | 2022-12-26T09:20:24Z | - |
| dc.date.issued | 2022-06 | - |
| dc.identifier.issn | 1226-1289 | - |
| dc.identifier.uri | https://scholarworks.gnu.ac.kr/handle/sw.gnu/2260 | - |
| dc.description.abstract | Physical barriers such as partitions can reduce airborne infection by preventing aerosol or droplets exhaled by one person from entering the breathing zone of another. However, if buoyancy effect occurred in a natural room, airborne pathogens rise vertically and spread horizontally. So, this study suggested ceiling fin system to prevent the spread of airborne pathogens due to buoyancy effect and investigated the effect of the ceiling fins in preventing the spread of airborne pathogens by STAR-CCM+ (computational fluid dynamics software). As the results of the study, the ceiling fins prevented the airflow recirculation around the ceiling. Also, implementation of ceiling fins reduced airborne pathogen concentrations (passive scalar concentrations of the simulation model) not only at breathing zone but also in the entire room by 14% and 11.7% respectively. These results indicate that implement of the ceiling fins to delay in spread and mixing of airborne pathogens in a room. | - |
| dc.format.extent | 8 | - |
| dc.language | 영어 | - |
| dc.language.iso | ENG | - |
| dc.publisher | 한국생활환경학회 | - |
| dc.title | Implementation of Ceiling Fin to Prevent the Spread of Airborne Pathogens by Buoyancy Effect | - |
| dc.title.alternative | Implementation of Ceiling Fin to Prevent the Spread of Airborne Pathogens by Buoyancy Effect | - |
| dc.type | Article | - |
| dc.publisher.location | 대한민국 | - |
| dc.identifier.doi | 10.21086/ksles.2022.6.29.3.297 | - |
| dc.identifier.bibliographicCitation | 한국생활환경학회지, v.29, no.3, pp 297 - 304 | - |
| dc.citation.title | 한국생활환경학회지 | - |
| dc.citation.volume | 29 | - |
| dc.citation.number | 3 | - |
| dc.citation.startPage | 297 | - |
| dc.citation.endPage | 304 | - |
| dc.identifier.kciid | ART002860259 | - |
| dc.description.isOpenAccess | N | - |
| dc.description.journalRegisteredClass | kci | - |
| dc.subject.keywordAuthor | Ceiling Fin | - |
| dc.subject.keywordAuthor | Airborne pathogen | - |
| dc.subject.keywordAuthor | Airborne infection | - |
| dc.subject.keywordAuthor | Buoyancy effect | - |
| dc.subject.keywordAuthor | CFD simulation | - |
Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.
Gyeongsang National University Central Library, 501, Jinju-daero, Jinju-si, Gyeongsangnam-do, 52828, Republic of Korea+82-55-772-0532
COPYRIGHT 2022 GYEONGSANG NATIONAL UNIVERSITY LIBRARY. ALL RIGHTS RESERVED.
Certain data included herein are derived from the © Web of Science of Clarivate Analytics. All rights reserved.
You may not copy or re-distribute this material in whole or in part without the prior written consent of Clarivate Analytics.