Cited 14 time in
Strain Measurements on a Cantilever Beam with Fiber Bragg Grating Sensors Using a Pair of Collimators
| DC Field | Value | Language |
|---|---|---|
| dc.contributor.author | Kang, Min-Kyu | - |
| dc.contributor.author | Park, Dong-Jin | - |
| dc.contributor.author | Lee, Seok-Soon | - |
| dc.date.accessioned | 2022-12-27T01:54:39Z | - |
| dc.date.available | 2022-12-27T01:54:39Z | - |
| dc.date.issued | 2012-03 | - |
| dc.identifier.issn | 2234-7593 | - |
| dc.identifier.issn | 2005-4602 | - |
| dc.identifier.uri | https://scholarworks.gnu.ac.kr/handle/sw.gnu/22316 | - |
| dc.description.abstract | Fiber bragg grating (FBG) sensors are currently in use in various,fields. However, it is difficult to use these sensors to obtain strain measurements at locations where it is not physically possible to connect the fibers to each other. In the present study, we performed strain measurements using many FBG sensors connected to a single optical fiber and a pair of collimators. The single optical fiber connected to the FBG sensors was installed on a cantilevered beam with another optical fiber line connected to a stationary optical interrogator. The two optical fiber lines were connected by a pair of collimators making use of the fact that light travels in a straight line through space. Our experiment demonstrated that the wavelength of the light changed linearly as it passed between the two collimators, and that this change increased with the applied strain. Accurate strain measurements could be obtained by applying a proposed collimator collection factor. | - |
| dc.format.extent | 4 | - |
| dc.language | 영어 | - |
| dc.language.iso | ENG | - |
| dc.publisher | KOREAN SOC PRECISION ENG | - |
| dc.title | Strain Measurements on a Cantilever Beam with Fiber Bragg Grating Sensors Using a Pair of Collimators | - |
| dc.type | Article | - |
| dc.publisher.location | 대한민국 | - |
| dc.identifier.doi | 10.1007/s12541-012-0059-6 | - |
| dc.identifier.scopusid | 2-s2.0-84863347413 | - |
| dc.identifier.wosid | 000300961800019 | - |
| dc.identifier.bibliographicCitation | INTERNATIONAL JOURNAL OF PRECISION ENGINEERING AND MANUFACTURING, v.13, no.3, pp 455 - 458 | - |
| dc.citation.title | INTERNATIONAL JOURNAL OF PRECISION ENGINEERING AND MANUFACTURING | - |
| dc.citation.volume | 13 | - |
| dc.citation.number | 3 | - |
| dc.citation.startPage | 455 | - |
| dc.citation.endPage | 458 | - |
| dc.type.docType | Article | - |
| dc.identifier.kciid | ART001635190 | - |
| dc.description.isOpenAccess | N | - |
| dc.description.journalRegisteredClass | scie | - |
| dc.description.journalRegisteredClass | scopus | - |
| dc.description.journalRegisteredClass | kci | - |
| dc.relation.journalResearchArea | Engineering | - |
| dc.relation.journalWebOfScienceCategory | Engineering, Manufacturing | - |
| dc.relation.journalWebOfScienceCategory | Engineering, Mechanical | - |
| dc.subject.keywordAuthor | Fiber bragg grating sensor | - |
| dc.subject.keywordAuthor | Collimator correction factor (CCF) | - |
Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.
Gyeongsang National University Central Library, 501, Jinju-daero, Jinju-si, Gyeongsangnam-do, 52828, Republic of Korea+82-55-772-0532
COPYRIGHT 2022 GYEONGSANG NATIONAL UNIVERSITY LIBRARY. ALL RIGHTS RESERVED.
Certain data included herein are derived from the © Web of Science of Clarivate Analytics. All rights reserved.
You may not copy or re-distribute this material in whole or in part without the prior written consent of Clarivate Analytics.
