Detailed Information

Cited 14 time in webofscience Cited 14 time in scopus
Metadata Downloads

Strain Measurements on a Cantilever Beam with Fiber Bragg Grating Sensors Using a Pair of Collimators

Full metadata record
DC Field Value Language
dc.contributor.authorKang, Min-Kyu-
dc.contributor.authorPark, Dong-Jin-
dc.contributor.authorLee, Seok-Soon-
dc.date.accessioned2022-12-27T01:54:39Z-
dc.date.available2022-12-27T01:54:39Z-
dc.date.issued2012-03-
dc.identifier.issn2234-7593-
dc.identifier.issn2005-4602-
dc.identifier.urihttps://scholarworks.gnu.ac.kr/handle/sw.gnu/22316-
dc.description.abstractFiber bragg grating (FBG) sensors are currently in use in various,fields. However, it is difficult to use these sensors to obtain strain measurements at locations where it is not physically possible to connect the fibers to each other. In the present study, we performed strain measurements using many FBG sensors connected to a single optical fiber and a pair of collimators. The single optical fiber connected to the FBG sensors was installed on a cantilevered beam with another optical fiber line connected to a stationary optical interrogator. The two optical fiber lines were connected by a pair of collimators making use of the fact that light travels in a straight line through space. Our experiment demonstrated that the wavelength of the light changed linearly as it passed between the two collimators, and that this change increased with the applied strain. Accurate strain measurements could be obtained by applying a proposed collimator collection factor.-
dc.format.extent4-
dc.language영어-
dc.language.isoENG-
dc.publisherKOREAN SOC PRECISION ENG-
dc.titleStrain Measurements on a Cantilever Beam with Fiber Bragg Grating Sensors Using a Pair of Collimators-
dc.typeArticle-
dc.publisher.location대한민국-
dc.identifier.doi10.1007/s12541-012-0059-6-
dc.identifier.scopusid2-s2.0-84863347413-
dc.identifier.wosid000300961800019-
dc.identifier.bibliographicCitationINTERNATIONAL JOURNAL OF PRECISION ENGINEERING AND MANUFACTURING, v.13, no.3, pp 455 - 458-
dc.citation.titleINTERNATIONAL JOURNAL OF PRECISION ENGINEERING AND MANUFACTURING-
dc.citation.volume13-
dc.citation.number3-
dc.citation.startPage455-
dc.citation.endPage458-
dc.type.docTypeArticle-
dc.identifier.kciidART001635190-
dc.description.isOpenAccessN-
dc.description.journalRegisteredClassscie-
dc.description.journalRegisteredClassscopus-
dc.description.journalRegisteredClasskci-
dc.relation.journalResearchAreaEngineering-
dc.relation.journalWebOfScienceCategoryEngineering, Manufacturing-
dc.relation.journalWebOfScienceCategoryEngineering, Mechanical-
dc.subject.keywordAuthorFiber bragg grating sensor-
dc.subject.keywordAuthorCollimator correction factor (CCF)-
Files in This Item
There are no files associated with this item.
Appears in
Collections
공학계열 > 기계항공우주공학부 > Journal Articles

qrcode