Detailed Information

Cited 0 time in webofscience Cited 0 time in scopus
Metadata Downloads

Three-dimensional volume assessment accuracy in computed tomography using a phantom

Authors
Kim, H.-S.Wang, J.-H.Lim, I.-H.Park, K.-T.Yeon, S.-C.Lee, H.-C.
Issue Date
2013
Keywords
CT; Slice thickness; Synthetic simulated tumor; Three dimensional volume
Citation
Journal of Veterinary Clinics, v.30, no.4, pp 268 - 272
Pages
5
Indexed
SCOPUS
KCI
Journal Title
Journal of Veterinary Clinics
Volume
30
Number
4
Start Page
268
End Page
272
URI
https://scholarworks.gnu.ac.kr/handle/sw.gnu/21767
ISSN
1598-298X
Abstract
The purpose of this study was to assess the effects of reconstruction kernel, and slice thickness on the accuracy of spiral CT-based volume assessment over a range of object sizes typical of synthetic simulated tumor. Spiral CT scanning was performed at various reconstruction kernels (soft tissue, standard, bone), and slice thickness (1, 2, 3 mm) using a phantom made of gelatin and 10 synthetic simulated tumors of different sizes (diameter 3.0-12.0 mm). Three-dimensional volume assessments were obtained using an automated software tool. Results were compared with the reference volume by calculating the percentage error. Statistical analysis was performed using ANOVA and setting statistical significance at P < 0.05. In general, smaller slice thickness and larger sphere diameters produced more accurate volume assessment than larger slice thickness and smaller sphere diameter. The measured volumes were larger than the actual volumes by a common factor depending on slice thickness; in 100HU simulated tumors that had statistically significant, 1 mm slice thickness produced on average 27.41%, 2 mm slice thickness produced 45.61%, 3 mm slice thickness produced 93.36% overestimates of volume. However, there was no statistically significant difference in volume error for spiral CT scans taken with techniques where only reconstruction kernel was changed. These results supported that synthetic simulated tumor size, slice thickness were significant parameters in determining volume measurement errors. For an accurate volumetric measurement of an object, it is critical to select an appropriate slice thickness and to consider the size of an object.
Files in This Item
There are no files associated with this item.
Appears in
Collections
수의과대학 > Department of Veterinary Medicine > Journal Articles

qrcode

Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.

Related Researcher

Researcher Lee, Hee Chun photo

Lee, Hee Chun
수의과대학 (수의학과)
Read more

Altmetrics

Total Views & Downloads

BROWSE