Detailed Information

Cited 0 time in webofscience Cited 0 time in scopus
Metadata Downloads

고속 고정밀 볼 스크류 구동에 따른 강제 냉각방식의 효과에 관한 연구

Full metadata record
DC Field Value Language
dc.contributor.author김수상-
dc.contributor.author류성기-
dc.contributor.author허철수-
dc.contributor.author김현구-
dc.date.accessioned2022-12-27T01:17:59Z-
dc.date.available2022-12-27T01:17:59Z-
dc.date.issued2013-
dc.identifier.issn1225-9071-
dc.identifier.issn2287-8769-
dc.identifier.urihttps://scholarworks.gnu.ac.kr/handle/sw.gnu/21547-
dc.description.abstractBall screw system is widely used as a precision mechanical linear actuator that translates rotational motion to linear motion for its high efficiency, great stiffness and long life. Recently, according to the requirements of high accuracy and stiffness, the pre-load on the ball screw which means of remove the backlash in the ball screw is usually used. Because of the preload which means the frictional resistance between the screw and nut, becomes a dominating heat source and it generates thermal deformation of ball screw which is the reason for low accuracy of the positioning decision. There are several methods to solve the problem that includes temperature control, thermal stable design and error compensation. In the past years, researchers focused on the error compensation technique for its ability to correct ball screw error effectively rather than the capabilities of careful machine design and manufacturing. Significant amounts of researches have been done to real-time error compensation. But in this paper, we developed a series of cooling methods to get thermal equilibrium in the ball screw system. So we find the optimum cooling type for improving positioning error which caused by thermal deformation in the ball screw system.-
dc.format.extent6-
dc.language한국어-
dc.language.isoKOR-
dc.publisher한국정밀공학회-
dc.title고속 고정밀 볼 스크류 구동에 따른 강제 냉각방식의 효과에 관한 연구-
dc.title.alternativeA Study on Effect of Various Cooling Methods in Motion of High-Precision Ball Screw-
dc.typeArticle-
dc.publisher.location대한민국-
dc.identifier.doi10.7736/KSPE.2013.30.3.254-
dc.identifier.bibliographicCitation한국정밀공학회지, v.30, no.3, pp 254 - 259-
dc.citation.title한국정밀공학회지-
dc.citation.volume30-
dc.citation.number3-
dc.citation.startPage254-
dc.citation.endPage259-
dc.identifier.kciidART001744496-
dc.description.isOpenAccessN-
dc.description.journalRegisteredClasskci-
dc.subject.keywordAuthorBall Screw-
dc.subject.keywordAuthorNut Cooling-
dc.subject.keywordAuthorCenter Hole Cooling (중공축 냉각)-
dc.subject.keywordAuthorThermal Distribution Imaging (열화상 사진)-
dc.subject.keywordAuthorThermal Deformation (열 변형)-
dc.subject.keywordAuthorStroke Condition (행정조건)-
Files in This Item
There are no files associated with this item.
Appears in
Collections
공학계열 > 기계항공우주공학부 > Journal Articles

qrcode

Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.

Related Researcher

Researcher Lyu, Sung Ki photo

Lyu, Sung Ki
대학원 (기계항공우주공학부)
Read more

Altmetrics

Total Views & Downloads

BROWSE