Detailed Information

Cited 0 time in webofscience Cited 0 time in scopus
Metadata Downloads

Comparison on Usefulness of Sampling Methods of Indoles in Airs from Swine Facility by Tenax-TA and SPME

Full metadata record
DC Field Value Language
dc.contributor.author유미선-
dc.contributor.author이재춘-
dc.contributor.author양성봉-
dc.contributor.author김두환-
dc.contributor.author조성백-
dc.contributor.author황옥화-
dc.date.accessioned2022-12-27T00:47:36Z-
dc.date.available2022-12-27T00:47:36Z-
dc.date.issued2013-
dc.identifier.issn1225-4517-
dc.identifier.issn2287-3503-
dc.identifier.urihttps://scholarworks.gnu.ac.kr/handle/sw.gnu/20922-
dc.description.abstractThe purpose of this study is to compare the sampling methods for monitoring indoles (phenol, p-cresol, indole and skatole) in airs of swine facility. As the collecting methods of indoles in air, Tenax-TA adsorption tube and solid phase microextraction (SPME) were examined. For the preparation of calibration curves of indoles concentrated in Tenax-TA, the standard indoles solutions were spiked in each of Tenax-TA tubes and thermally desorbed (ATD) into a gas chromatograph combined with mass detector (GC/MS). And for the preparation of calibration curves by SPME, indoles in the standard gaseous solution prepared by evaporating the aqueous solution that contained indoles into a polyester sampling bag were extracted with SPME fiber and subsequently analyzed by the GC/MS. Two sampling methods were evaluated for extracting indoles present in swine building environments. Results indicated that the SPME method using Polydimethylsiloxane/ Divinylbenzene (PDMS/DVB) fiber was more effective than Tenax-TA method in extracting indoles. The gas chromatographic analysis showed that the linearities of calibration curves and detection limits were useful for detection of indoles in swine airs. The field tests also showed that considerably different levels of indoles were present in various parts of the swine building.-
dc.format.extent11-
dc.language영어-
dc.language.isoENG-
dc.publisher한국환경과학회-
dc.titleComparison on Usefulness of Sampling Methods of Indoles in Airs from Swine Facility by Tenax-TA and SPME-
dc.title.alternativeComparison on Usefulness of Sampling Methods of Indoles in Airs from Swine Facility by Tenax-TA and SPME-
dc.typeArticle-
dc.publisher.location대한민국-
dc.identifier.doi10.5322/JESI.2013.22.12.1539-
dc.identifier.bibliographicCitation한국환경과학회지, v.22, no.12, pp 1539 - 1549-
dc.citation.title한국환경과학회지-
dc.citation.volume22-
dc.citation.number12-
dc.citation.startPage1539-
dc.citation.endPage1549-
dc.identifier.kciidART001840860-
dc.description.isOpenAccessY-
dc.description.journalRegisteredClasskci-
dc.subject.keywordAuthorSwine odor-
dc.subject.keywordAuthorIndoles-
dc.subject.keywordAuthorTenax-TA-
dc.subject.keywordAuthorSPME-
Files in This Item
There are no files associated with this item.
Appears in
Collections
농업생명과학대학 > 축산과학부 > Journal Articles

qrcode

Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.

Related Researcher

Researcher Kim, Doo Hwan photo

Kim, Doo Hwan
농업생명과학대학 (축산과학부)
Read more

Altmetrics

Total Views & Downloads

BROWSE