Comparative Analysis of Flux-Reversal Motors with Six-Switch and Four-Switch Convertersopen access
- Authors
- Kang, Hyun-Soo; Lee, Byoung-Kuk; Kim, Tae Heoung
- Issue Date
- Mar-2013
- Publisher
- KOREAN MAGNETICS SOC
- Keywords
- flux-reversal machine; finite element method; 4-switch
- Citation
- JOURNAL OF MAGNETICS, v.18, no.1, pp 50 - 56
- Pages
- 7
- Indexed
- SCIE
SCOPUS
KCI
- Journal Title
- JOURNAL OF MAGNETICS
- Volume
- 18
- Number
- 1
- Start Page
- 50
- End Page
- 56
- URI
- https://scholarworks.gnu.ac.kr/handle/sw.gnu/20778
- DOI
- 10.4283/JMAG.2013.18.1.050
- ISSN
- 1226-1750
2233-6656
- Abstract
- In this paper, the 6-switch inverter for the Flux-Reversal Motor (FRM) has been presented and compared to the 4-switch inverter for the FRM, which is more popular in cost effective applications. To analyze the FRM, we adopted the two-dimensional time-stepped voltage source finite element method (FEM) that uses the actual pulse width modulation (PWM) voltage waveforms as the input data. As the FRM characteristic analysis of actual pwm voltage input, the torque ripples and iron losses (eddy current and hysteresis loss) of the FRM can be precisely calculated. With the simulated and experimental results, the performance and limitations of the 4-switch FRM which is the cost effective drive compared to the 6-switch FRM drive are provided in more detail.