Detailed Information

Cited 12 time in webofscience Cited 15 time in scopus
Metadata Downloads

Spurious Elevation of Glucose Concentration during Administration of High Dose of Ascorbic Acid in a Patient with Type 2 Diabetes on Hemodialysis

Full metadata record
DC Field Value Language
dc.contributor.authorKim, Soo Kyoung-
dc.contributor.authorHahm, Jong Ryeal-
dc.contributor.authorKim, Ho-Su-
dc.contributor.authorKim, Sungsu-
dc.contributor.authorJung, Tae Sik-
dc.contributor.authorJung, Jung Hwa-
dc.contributor.authorLee, Hye Ryun-
dc.contributor.authorKim, Deok Ryong-
dc.date.accessioned2022-12-27T00:21:32Z-
dc.date.available2022-12-27T00:21:32Z-
dc.date.issued2013-09-
dc.identifier.issn0513-5796-
dc.identifier.issn1976-2437-
dc.identifier.urihttps://scholarworks.gnu.ac.kr/handle/sw.gnu/20484-
dc.description.abstractWe describe herein a case of life-threatening hypoglycemia due to spurious elevation of glucose concentration during the administration of ascorbic acid in a type 2 diabetic patient. A 31-year-old female was admitted for proliferative diabetic retinopathy treatment and prescribed high dose ascorbic acid. During hospitalization, she suddenly lost her consciousness and her glucose concentration was 291 mg/dL, measured using self-monitoring blood glucose (SMBG) device, while venous blood glucose concentration was 12 mg/dL. After intravenous injection of 50% glucose solution, the patient became alert. We reasoned that glucose measurement by SMBG device was interfered by ascorbic acid. Physicians should be aware of this interference; high dose ascorbic acid may cause spurious elevation of glucose concentration when measuring with SMBG devices.-
dc.format.extent4-
dc.language영어-
dc.language.isoENG-
dc.publisher연세대학교의과대학-
dc.titleSpurious Elevation of Glucose Concentration during Administration of High Dose of Ascorbic Acid in a Patient with Type 2 Diabetes on Hemodialysis-
dc.typeArticle-
dc.publisher.location대한민국-
dc.identifier.doi10.3349/ymj.2013.54.5.1289-
dc.identifier.scopusid2-s2.0-84881008343-
dc.identifier.wosid000326128500031-
dc.identifier.bibliographicCitationYonsei Medical Journal, v.54, no.5, pp 1289 - 1292-
dc.citation.titleYonsei Medical Journal-
dc.citation.volume54-
dc.citation.number5-
dc.citation.startPage1289-
dc.citation.endPage1292-
dc.type.docTypeArticle-
dc.identifier.kciidART001794724-
dc.description.isOpenAccessN-
dc.description.journalRegisteredClassscie-
dc.description.journalRegisteredClassscopus-
dc.description.journalRegisteredClasskci-
dc.relation.journalResearchAreaGeneral & Internal Medicine-
dc.relation.journalWebOfScienceCategoryMedicine, General & Internal-
dc.subject.keywordPlusBLOOD-GLUCOSE-
dc.subject.keywordPlusPERITONEAL-DIALYSIS-
dc.subject.keywordPlusTEST STRIPS-
dc.subject.keywordPlusICODEXTRIN-
dc.subject.keywordAuthorSelf-monitoring of blood glucose-
dc.subject.keywordAuthorascorbic acid-
dc.subject.keywordAuthorhypoglycemia-
Files in This Item
There are no files associated with this item.
Appears in
Collections
의학계열 > 의학과 > Journal Articles
College of Medicine > Department of Medicine > Journal Articles

qrcode

Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.

Related Researcher

Researcher Kim, Deok Ryong photo

Kim, Deok Ryong
의과대학 (의학과)
Read more

Altmetrics

Total Views & Downloads

BROWSE