Detailed Information

Cited 17 time in webofscience Cited 21 time in scopus
Metadata Downloads

Autologous Platelet-Poor Plasma Gel for Injection Laryngoplasty

Full metadata record
DC Field Value Language
dc.contributor.authorWoo, Seung Hoon-
dc.contributor.authorKim, Jin Pyeong-
dc.contributor.authorPark, Jung Je-
dc.contributor.authorChung, Phil-Sang-
dc.contributor.authorLee, Sang-Hyuk-
dc.contributor.authorJeong, Han-Sin-
dc.date.accessioned2022-12-27T00:19:08Z-
dc.date.available2022-12-27T00:19:08Z-
dc.date.issued2013-11-01-
dc.identifier.issn0513-5796-
dc.identifier.issn1976-2437-
dc.identifier.urihttps://scholarworks.gnu.ac.kr/handle/sw.gnu/20378-
dc.description.abstractPurpose: To overcome the potential disadvantages of the use of foreign materials and autologous fat or collagen, we introduce here an autologous plasma gel for injection laryngoplasty. The purpose of this study was to present a new injection material, a plasma gel, and to discuss its clinical effectiveness. Materials and Methods: From 2 mL of blood, the platelet poor serum layer was collected and heated at 100 degrees C for 12 min to form a plasma gel. The plasma gel was then injected into a targeted site; the safety and efficacy thereof were evaluated in 30 rats. We also conducted a phase I/II clinical study of plasma gel injection laryngoplasty in 11 unilateral vocal fold paralysis patients. Results: The plasma gel was semi-solid and an easily injectable material. Of note, plasma gel maintains the same consistency for up to 1 year in a sealed bottle. However, exposure to room air causes the plasma gel to disappear within 1 month. In our animal study, the autologous plasma gel remained in situ for 6 months in animals with minimal inflammation. Clinical study showed that vocal cord palsy was well compensated for with the plasma gel in all patients at two months after injection with no significant complications. Jitter, shimmer, maximum, maximum phonation time (MPT) and mean voice handicap index (VHI) also improved significantly after plasma gel injection. However, because the injected plasma gel was gradually absorbed, 6 patients needed another injection, while the gel remained in place in 2 patients. Conclusion: Injection laryngoplasty with autologous plasma gel may be a useful and safe treatment option for temporary vocal cord palsy.-
dc.format.extent8-
dc.language영어-
dc.language.isoENG-
dc.publisherYONSEI UNIV COLL MEDICINE-
dc.titleAutologous Platelet-Poor Plasma Gel for Injection Laryngoplasty-
dc.typeArticle-
dc.publisher.location대한민국-
dc.identifier.doi10.3349/ymj.2013.54.6.1516-
dc.identifier.scopusid2-s2.0-84886512462-
dc.identifier.wosid000326415500030-
dc.identifier.bibliographicCitationYONSEI MEDICAL JOURNAL, v.54, no.6, pp 1516 - 1523-
dc.citation.titleYONSEI MEDICAL JOURNAL-
dc.citation.volume54-
dc.citation.number6-
dc.citation.startPage1516-
dc.citation.endPage1523-
dc.type.docTypeArticle-
dc.identifier.kciidART001813955-
dc.description.isOpenAccessY-
dc.description.journalRegisteredClassscie-
dc.description.journalRegisteredClassscopus-
dc.description.journalRegisteredClasskci-
dc.relation.journalResearchAreaGeneral & Internal Medicine-
dc.relation.journalWebOfScienceCategoryMedicine, General & Internal-
dc.subject.keywordPlusVOCAL FOLD INJECTION-
dc.subject.keywordPlusRICH PLASMA-
dc.subject.keywordPlusFAT INJECTION-
dc.subject.keywordPlusAUGMENTATION-
dc.subject.keywordPlusEFFICIENCY-
dc.subject.keywordPlusBIOLOGY-
dc.subject.keywordAuthorPlasma gel-
dc.subject.keywordAuthorinjection-
dc.subject.keywordAuthorvocal cord palsy-
dc.subject.keywordAuthorlaryngoplasty-
dc.subject.keywordAuthoracoustical analysis-
Files in This Item
There are no files associated with this item.
Appears in
Collections
College of Medicine > Department of Medicine > Journal Articles

qrcode

Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.

Related Researcher

Researcher Park, Jung Je photo

Park, Jung Je
의과대학 (의학과)
Read more

Altmetrics

Total Views & Downloads

BROWSE