Detailed Information

Cited 28 time in webofscience Cited 29 time in scopus
Metadata Downloads

Clinical Evaluation of BacT/Alert FA Plus and FN Plus Bottles Compared with Standard Bottles

Full metadata record
DC Field Value Language
dc.contributor.authorLee, Dong-Hyun-
dc.contributor.authorKim, Seong Chun-
dc.contributor.authorBae, In-Gyu-
dc.contributor.authorKoh, Eun-Ha-
dc.contributor.authorKim, Sunjoo-
dc.date.accessioned2022-12-27T00:18:22Z-
dc.date.available2022-12-27T00:18:22Z-
dc.date.issued2013-12-
dc.identifier.issn0095-1137-
dc.identifier.issn1098-660X-
dc.identifier.urihttps://scholarworks.gnu.ac.kr/handle/sw.gnu/20346-
dc.description.abstractThe performance of the BacT/Alert FA Plus and FN Plus resin bottles was evaluated in comparison with that of standard aerobic (SA) and standard anaerobic (SN) bottles. Twenty milliliters of blood from adult patients was equally distributed into four types of bottles: FA Plus, FN Plus, SA, and SN. The detection of clinically significant organisms and the time to detection (TTD) were monitored for each bottle. Among the 3,103 blood culture sets that were requested, the blood volume of each bottle was over 4 ml in 1,481 sets (47.7%). Among these 1,481 sets, 158 cultures grew in the FA Plus and SA bottles, and 136 grew in the FN Plus and SN bottles. Growth in only one type of bottle was more commonly observed for the FA Plus (n = 38) than for the SA (n = 14) (P = 0.001) bottles and for the FN Plus (n = 27) than for the SN (n = 10) (P = 0.008) bottles. Gram-negative bacilli were more frequently isolated in the resin bottles (P < 0.05). The skin contamination rate was 1.2% in the resin bottles and the standard bottles. The mean TTD was 11.1 h in the FA Plus bottles versus 13.1 h in the SA bottles (P < 0.001) and 12.0 h in the FN Plus bottles versus 12.8 h in the SN bottles (P = 0.083). Clinically significant bacteria, including Gram-negative bacilli, were isolated more frequently from the resin bottles than from the standard bottles. Clinically significant bacteria were detected faster using the aerobic resin bottles than using the standard aerobic bottles. This finding might not be applicable to the standard-practice 10-ml protocol for each bottle because the results from using a smaller volume (5 ml) might be less pronounced.-
dc.format.extent6-
dc.language영어-
dc.language.isoENG-
dc.publisherAMER SOC MICROBIOLOGY-
dc.titleClinical Evaluation of BacT/Alert FA Plus and FN Plus Bottles Compared with Standard Bottles-
dc.typeArticle-
dc.publisher.location미국-
dc.identifier.doi10.1128/JCM.01935-13-
dc.identifier.scopusid2-s2.0-84889812726-
dc.identifier.wosid000327147100041-
dc.identifier.bibliographicCitationJOURNAL OF CLINICAL MICROBIOLOGY, v.51, no.12, pp 4150 - 4155-
dc.citation.titleJOURNAL OF CLINICAL MICROBIOLOGY-
dc.citation.volume51-
dc.citation.number12-
dc.citation.startPage4150-
dc.citation.endPage4155-
dc.type.docTypeArticle-
dc.description.isOpenAccessY-
dc.description.journalRegisteredClasssci-
dc.description.journalRegisteredClassscie-
dc.description.journalRegisteredClassscopus-
dc.relation.journalResearchAreaMicrobiology-
dc.relation.journalWebOfScienceCategoryMicrobiology-
dc.subject.keywordPlusBLOOD CULTURE BOTTLES-
dc.subject.keywordPlusINFECTIONS-
dc.subject.keywordPlusBACTEREMIA-
dc.subject.keywordPlusAEROBIC/F-
Files in This Item
There are no files associated with this item.
Appears in
Collections
College of Medicine > Department of Medicine > Journal Articles

qrcode

Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.

Related Researcher

Researcher Kim, Sun Joo photo

Kim, Sun Joo
의과대학 (의학과)
Read more

Altmetrics

Total Views & Downloads

BROWSE