Cited 1 time in
Development of new effectiveness assessment indices of pumped storage power plant
| DC Field | Value | Language |
|---|---|---|
| dc.contributor.author | Lee, S.-H. | - |
| dc.contributor.author | Choi, J.-S. | - |
| dc.contributor.author | Cha, J.-M. | - |
| dc.contributor.author | Kim, D. | - |
| dc.date.accessioned | 2022-12-27T00:04:47Z | - |
| dc.date.available | 2022-12-27T00:04:47Z | - |
| dc.date.issued | 2014 | - |
| dc.identifier.issn | 1975-8359 | - |
| dc.identifier.issn | 2287-4364 | - |
| dc.identifier.uri | https://scholarworks.gnu.ac.kr/handle/sw.gnu/20140 | - |
| dc.description.abstract | The pumped storage power plants have excellent load following characteristics. It can also be committed quickly for synchronous reserve when it is in the generating mode because it can readily increase its generating power, consequently, increases the overall system reliability. There are strong incentives for standing the system reliability. Additionally, CO2 emission can be typically impacted due to operation of pumped generators. The increase or decrease of CO2 depends on the generation mix. This paper proposes evaluation of reliability, economy and environment of power system considering pumped generator. This paper describes three case studies of the reliability and economy and environment according to capacity factor and storage capacity of pumped generators. The probabilistic production simulation model is used in this paper. The practicality and effectiveness of the proposed approach are demonstrated by simulation studies for a real size power system model on the 5th power plan in Korea. | - |
| dc.format.extent | 8 | - |
| dc.language | 한국어 | - |
| dc.language.iso | KOR | - |
| dc.publisher | Korean Institute of Electrical Engineers | - |
| dc.title | Development of new effectiveness assessment indices of pumped storage power plant | - |
| dc.type | Article | - |
| dc.publisher.location | 대한민국 | - |
| dc.identifier.doi | 10.5370/KIEE.2014.63.7.867 | - |
| dc.identifier.scopusid | 2-s2.0-84905513459 | - |
| dc.identifier.bibliographicCitation | Transactions of the Korean Institute of Electrical Engineers, v.63, no.7, pp 867 - 874 | - |
| dc.citation.title | Transactions of the Korean Institute of Electrical Engineers | - |
| dc.citation.volume | 63 | - |
| dc.citation.number | 7 | - |
| dc.citation.startPage | 867 | - |
| dc.citation.endPage | 874 | - |
| dc.type.docType | Article | - |
| dc.identifier.kciid | ART001894460 | - |
| dc.description.isOpenAccess | Y | - |
| dc.description.journalRegisteredClass | scopus | - |
| dc.description.journalRegisteredClass | kci | - |
| dc.subject.keywordAuthor | Energy storage system(ess) | - |
| dc.subject.keywordAuthor | New effectiveness assessment algorithm | - |
| dc.subject.keywordAuthor | Performance index (pi) | - |
| dc.subject.keywordAuthor | Pumped storage power plant(pspp) | - |
Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.
Gyeongsang National University Central Library, 501, Jinju-daero, Jinju-si, Gyeongsangnam-do, 52828, Republic of Korea+82-55-772-0532
COPYRIGHT 2022 GYEONGSANG NATIONAL UNIVERSITY LIBRARY. ALL RIGHTS RESERVED.
Certain data included herein are derived from the © Web of Science of Clarivate Analytics. All rights reserved.
You may not copy or re-distribute this material in whole or in part without the prior written consent of Clarivate Analytics.