Cited 0 time in
부산광역시 공동주택의 외피구조에 따른 에너지 소비특성 분석
| DC Field | Value | Language |
|---|---|---|
| dc.contributor.author | 이정재 | - |
| dc.contributor.author | 김환용 | - |
| dc.contributor.author | 김승희 | - |
| dc.date.accessioned | 2022-12-26T23:47:50Z | - |
| dc.date.available | 2022-12-26T23:47:50Z | - |
| dc.date.issued | 2014 | - |
| dc.identifier.issn | 1598-6411 | - |
| dc.identifier.issn | 2508-3562 | - |
| dc.identifier.uri | https://scholarworks.gnu.ac.kr/handle/sw.gnu/19759 | - |
| dc.description.abstract | In this paper we made energy consumption units of glass curtain wall type apartment and general apartment in Busan metropolitan city and compared energy consumption characteristics by building envelope. The monthly electricity consumption units of general apartment were shown in the range of 1.16~1.51kWh/m2·mon which were indicated higher value in January, February, August and September with little variation. On the other hand, in case of glass curtain wall type apartment, monthly electricity consumption units were represented in the range of 1.91~7.07kWh/m2·mon with significant fluctuations monthly, which were outstandingly high in July, August and September. The monthly city gas consumption units of general apartment were found to be in the range of 1.79~18.07MJ/m2·mon, while glass curtain wall type apartment were within 0.94~19.91MJ/m2·mon. City gas consumption units from December to March were shown highly in both type apartments. The monthly energy consumption units of general apartment were found to be within 14.23~30.69MJ/m2·mon, while glass curtain wall type apartment were within 24.49~68.9MJ/m2·mon. Energy consumption units of glass curtain wall type apartment were suggested 4.84 times higher than those of general apartment. | - |
| dc.format.extent | 8 | - |
| dc.language | 한국어 | - |
| dc.language.iso | KOR | - |
| dc.publisher | 한국태양에너지학회 | - |
| dc.title | 부산광역시 공동주택의 외피구조에 따른 에너지 소비특성 분석 | - |
| dc.title.alternative | A Study on the Energy Consumption Characteristic by Building Envelope of Apartment Housing in Busan Metropolitan City | - |
| dc.type | Article | - |
| dc.publisher.location | 대한민국 | - |
| dc.identifier.bibliographicCitation | 한국태양에너지학회 논문집, v.34, no.4, pp 75 - 82 | - |
| dc.citation.title | 한국태양에너지학회 논문집 | - |
| dc.citation.volume | 34 | - |
| dc.citation.number | 4 | - |
| dc.citation.startPage | 75 | - |
| dc.citation.endPage | 82 | - |
| dc.identifier.kciid | ART001906271 | - |
| dc.description.isOpenAccess | N | - |
| dc.description.journalRegisteredClass | kci | - |
| dc.subject.keywordAuthor | 에너지원단위(Energy Consumption Unit) | - |
| dc.subject.keywordAuthor | 에너지 소비특성(Energy Consumption Charateristic) | - |
| dc.subject.keywordAuthor | 공동주택(Apartment Housing) | - |
| dc.subject.keywordAuthor | 외피구조(Building Envelope) | - |
| dc.subject.keywordAuthor | 커튼월(Curtain Wall) | - |
| dc.subject.keywordAuthor | 부산광역시(Busan Metropolitan City) | - |
Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.
Gyeongsang National University Central Library, 501, Jinju-daero, Jinju-si, Gyeongsangnam-do, 52828, Republic of Korea+82-55-772-0534
COPYRIGHT 2022 GYEONGSANG NATIONAL UNIVERSITY LIBRARY. ALL RIGHTS RESERVED.
Certain data included herein are derived from the © Web of Science of Clarivate Analytics. All rights reserved.
You may not copy or re-distribute this material in whole or in part without the prior written consent of Clarivate Analytics.