Cited 0 time in
대학건물 실내 에어로졸입자의 입경별 질량농도 특성
| DC Field | Value | Language |
|---|---|---|
| dc.contributor.author | 서정민 | - |
| dc.contributor.author | 왕빈 | - |
| dc.contributor.author | 장성호 | - |
| dc.contributor.author | 박정호 | - |
| dc.contributor.author | 최금찬 | - |
| dc.date.accessioned | 2022-12-26T23:20:28Z | - |
| dc.date.available | 2022-12-26T23:20:28Z | - |
| dc.date.issued | 2014 | - |
| dc.identifier.issn | 2384-132x | - |
| dc.identifier.issn | 2289-0564 | - |
| dc.identifier.uri | https://scholarworks.gnu.ac.kr/handle/sw.gnu/19259 | - |
| dc.description.abstract | Objective: Based on the fact that fine particles are more likely to produce negative influences onthe health of occupants as well as the quality of indoor air compared to coarse particles, it is critical to determine concentrations of aerosol particles with different sizes. Thus, this study focused on the size distribution and concentrations of aerosol particles in university buildings. Method: Aerosol particles in indoor air were collected from four areas: corridors in buildings (In-CO), lecture rooms(In-RO), laboratories(In-LR), and a cafeteria(In-RE). Samples were also collected from outside for comparison between the concentrations of indoor and outdoor particles. For the collection of the samples, an eight stage non-viable cascade impactor was used. Result: The average concentration of PM10 in the samples collected from indoor areas was 34.65-91.08 μg/m3,and the average for PM2.5 was 22.65-60.40 μg/m3. The concentrations of the aerosol particles in the corridors, lecture rooms, and laboratories were relatively higher than the concentrations collected from other areas. Furthermore, in terms of mass median aerodynamic diameter(MMAD), the corridors and lecture rooms had higher numbers due to their characteristics, showing 2.36 μm and 2.11 μm, respectively. Laboratories running an electrolysis experiment showed 1.58 μm, and the cafeteria with regular maintenance and ventilation had 1.96 μm. Conclusion: The results showed that the PM10 concentrations of all samples did not exceed indoor air quality standards. However, the PM2.5 concentration was over the standard and, in particular, the concentration of fine particles collected from the laboratories was relatively higher, which could be an issue for the occupants. Therefore, it is important to improve the quality of the indoor air in university buildings. | - |
| dc.format.extent | 9 | - |
| dc.language | 한국어 | - |
| dc.language.iso | KOR | - |
| dc.publisher | 한국산업보건학회 | - |
| dc.title | 대학건물 실내 에어로졸입자의 입경별 질량농도 특성 | - |
| dc.title.alternative | Characteristics of Size-segregated Mass Concentrations of Indoor Aerosol Particles in University Buildings | - |
| dc.type | Article | - |
| dc.publisher.location | 대한민국 | - |
| dc.identifier.doi | 10.15269/JKSOEH.2014.24.4.453 | - |
| dc.identifier.bibliographicCitation | 한국산업보건학회지, v.24, no.4, pp 453 - 461 | - |
| dc.citation.title | 한국산업보건학회지 | - |
| dc.citation.volume | 24 | - |
| dc.citation.number | 4 | - |
| dc.citation.startPage | 453 | - |
| dc.citation.endPage | 461 | - |
| dc.identifier.kciid | ART001951227 | - |
| dc.description.isOpenAccess | Y | - |
| dc.description.journalRegisteredClass | kci | - |
| dc.subject.keywordAuthor | Cascade impactor | - |
| dc.subject.keywordAuthor | indoor aerosol particle | - |
| dc.subject.keywordAuthor | MMAD | - |
| dc.subject.keywordAuthor | university building | - |
Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.
Gyeongsang National University Central Library, 501, Jinju-daero, Jinju-si, Gyeongsangnam-do, 52828, Republic of Korea+82-55-772-0532
COPYRIGHT 2022 GYEONGSANG NATIONAL UNIVERSITY LIBRARY. ALL RIGHTS RESERVED.
Certain data included herein are derived from the © Web of Science of Clarivate Analytics. All rights reserved.
You may not copy or re-distribute this material in whole or in part without the prior written consent of Clarivate Analytics.