Effects of macro and micro roughness in forced convective heat transfer
| DC Field | Value | Language |
|---|---|---|
| dc.contributor.author | Nine, Md J. | - |
| dc.contributor.author | Munkhbayar, B. | - |
| dc.contributor.author | Chung, Hanshik | - |
| dc.contributor.author | Jeong, Hyomin | - |
| dc.date.accessioned | 2022-12-26T23:20:04Z | - |
| dc.date.available | 2022-12-26T23:20:04Z | - |
| dc.date.issued | 2014-01 | - |
| dc.identifier.issn | 0735-1933 | - |
| dc.identifier.issn | 1879-0178 | - |
| dc.identifier.uri | https://scholarworks.gnu.ac.kr/handle/sw.gnu/19236 | - |
| dc.description.abstract | The article reports a comparative study of macro and micro type artificial roughness in convective heat transfer performance under laminar and low turbulent regime. Circular ribs with different rib height to channel height ratios (e/H = 0.05, 0.1, 0.15) fabricated on copper substrate are introduced as macro type roughness whereas copper (Cu) nano-porous layer (avg. thickness about 5 mu m) is considered as micro roughness. Surface heat transfer and friction characteristics are investigated under different scale roughnesses on one principle wall of a rectangular channel having an aspect ratio (AR) of 7.5. Result shows that the average turbulence intensity between two ribs decreases with decreasing roughness height. On the other hand, nano-porous layer provides significant heat transfer efficiency (about maximum 42% more than bare copper plate) under laminar and low turbulent region without inducing significant turbulence into the channel. Nano-porous layer less than 5 pm is found to increase heat transfer surface area significantly that influences the dynamic behaviors of working fluids in the vicinity of heat transfer wall. (C) 2013 Elsevier Ltd. All rights reserved. | - |
| dc.format.extent | 8 | - |
| dc.language | 영어 | - |
| dc.language.iso | ENG | - |
| dc.publisher | PERGAMON-ELSEVIER SCIENCE LTD | - |
| dc.title | Effects of macro and micro roughness in forced convective heat transfer | - |
| dc.type | Article | - |
| dc.publisher.location | 영국 | - |
| dc.identifier.doi | 10.1016/j.icheatmasstransfer.2013.11.004 | - |
| dc.identifier.scopusid | 2-s2.0-84903841734 | - |
| dc.identifier.wosid | 000344711900010 | - |
| dc.identifier.bibliographicCitation | INTERNATIONAL COMMUNICATIONS IN HEAT AND MASS TRANSFER, v.50, pp 77 - 84 | - |
| dc.citation.title | INTERNATIONAL COMMUNICATIONS IN HEAT AND MASS TRANSFER | - |
| dc.citation.volume | 50 | - |
| dc.citation.startPage | 77 | - |
| dc.citation.endPage | 84 | - |
| dc.type.docType | Article | - |
| dc.description.isOpenAccess | N | - |
| dc.description.journalRegisteredClass | scie | - |
| dc.description.journalRegisteredClass | scopus | - |
| dc.relation.journalResearchArea | Thermodynamics | - |
| dc.relation.journalResearchArea | Mechanics | - |
| dc.relation.journalWebOfScienceCategory | Thermodynamics | - |
| dc.relation.journalWebOfScienceCategory | Mechanics | - |
| dc.subject.keywordPlus | TURBULENT-FLOW | - |
| dc.subject.keywordPlus | FRICTION | - |
| dc.subject.keywordPlus | CHANNELS | - |
| dc.subject.keywordPlus | RIBS | - |
| dc.subject.keywordPlus | TUBES | - |
| dc.subject.keywordAuthor | Rectangular duct | - |
| dc.subject.keywordAuthor | Circular rib | - |
| dc.subject.keywordAuthor | Micro roughness | - |
| dc.subject.keywordAuthor | Friction factor | - |
| dc.subject.keywordAuthor | Heat transfer | - |
Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.
Gyeongsang National University Central Library, 501, Jinju-daero, Jinju-si, Gyeongsangnam-do, 52828, Republic of Korea+82-55-772-0532
COPYRIGHT 2022 GYEONGSANG NATIONAL UNIVERSITY LIBRARY. ALL RIGHTS RESERVED.
Certain data included herein are derived from the © Web of Science of Clarivate Analytics. All rights reserved.
You may not copy or re-distribute this material in whole or in part without the prior written consent of Clarivate Analytics.