Detailed Information

Cited 10 time in webofscience Cited 10 time in scopus
Metadata Downloads

Evaluation of the Accuracy of the EasyTest (TM) Malaria Pf/Pan Ag, a Rapid Diagnostic Test, in UgandaEvaluation of the accuracy of the easy test ™ Malaria Pf/pan Ag, a rapid diagnostic test, in Uganda

Other Titles
Evaluation of the accuracy of the easy test ™ Malaria Pf/pan Ag, a rapid diagnostic test, in Uganda
Authors
Chong, Chom-KyuCho, Pyo YunNa, Byoung-KukAhn, Seong KyuKim, Jin SuLee, Jin-SooLee, Sung-KeunHan, Eun-TaekKim, Hak-YongPark, Yun-KyuCha, Seok HoKim, Tong-Soo
Issue Date
Oct-2014
Publisher
대한기생충학ㆍ열대의학회
Keywords
Plasmodium falciparum; rapid diagnostic test; malaria; point-of-care testing; field test; Uganda
Citation
The Korean Journal of Parasitology, v.52, no.5, pp 501 - 505
Pages
5
Indexed
SCIE
SCOPUS
KCI
Journal Title
The Korean Journal of Parasitology
Volume
52
Number
5
Start Page
501
End Page
505
URI
https://scholarworks.gnu.ac.kr/handle/sw.gnu/18732
DOI
10.3347/kjp.2014.52.5.501
ISSN
0023-4001
1738-0006
Abstract
In recent years, rapid diagnostic tests (RDTs) have been widely used for malaria detection, primarily because of their simple operation, fast results, and straightforward interpretation. The Asan EasyTest (TM) Malaria Pf/Pan Ag is one of the most commonly used malaria RDTs in several countries, including Korea and India. In this study, we tested the diagnostic performance of this RDT in Uganda to evaluate its usefulness for field diagnosis of malaria in this country. Microscopic and PCR analyses, and the Asan EasyTest (TM) Malaria Pt/Pan Ag rapid diagnostic test, were performed on blood samples from 185 individuals with suspected malaria in several villages in Uganda. Compared to the microscopic analysis, the sensitivity of the RDT to detect malaria infection was 95.8% and 83.3% for Plasmodium falciparum and non-P falciparum, respectively. Although the diagnostic sensitivity of the RDT decreased when parasitemia was <= 500 parasites/mu l, it showed 96.8% sensitivity (98.4% for P. falciparum and 93.8% for non-P. falciparum) in blood samples with parasitemia. >= 100 parasites/mu l. The specificity of the RDT was 97.3% for P falciparum and 97.3% for non-P falciparum. These results collectively suggest that the accuracy of the Asan EasyTest (TM) Malaria Pf/Pan Ag makes it an effective point-of-care diagnostic tool for malaria in Uganda.
Files in This Item
There are no files associated with this item.
Appears in
Collections
College of Medicine > Department of Medicine > Journal Articles

qrcode

Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.

Related Researcher

Researcher Na, Byoung Kuk photo

Na, Byoung Kuk
의과대학 (의학과)
Read more

Altmetrics

Total Views & Downloads

BROWSE