Cited 37 time in
Comparison Study of the Eosin-5 '-Maleimide Binding Test, Flow Cytometric Osmotic Fragility Test, and Cryohemolysis Test in the Diagnosis of Hereditary Spherocytosis
| DC Field | Value | Language |
|---|---|---|
| dc.contributor.author | Park, Sang Hyuk | - |
| dc.contributor.author | Park, Chan-Jeoung | - |
| dc.contributor.author | Lee, Bo-Ra | - |
| dc.contributor.author | Cho, Young-Uk | - |
| dc.contributor.author | Jang, Seongsoo | - |
| dc.contributor.author | Kim, Nayoung | - |
| dc.contributor.author | Koh, Kyung-Nam | - |
| dc.contributor.author | Im, Ho-Joon | - |
| dc.contributor.author | Seo, Jong-Jin | - |
| dc.contributor.author | Park, Eun Sil | - |
| dc.contributor.author | Lee, Ji Won | - |
| dc.contributor.author | Yoo, Keon Hee | - |
| dc.contributor.author | Jung, Hye Lim | - |
| dc.date.accessioned | 2022-12-26T22:51:45Z | - |
| dc.date.available | 2022-12-26T22:51:45Z | - |
| dc.date.issued | 2014-10 | - |
| dc.identifier.issn | 0002-9173 | - |
| dc.identifier.issn | 1943-7722 | - |
| dc.identifier.uri | https://scholarworks.gnu.ac.kr/handle/sw.gnu/18731 | - |
| dc.description.abstract | Objectives: Current guidelines recommend the eosin-5'maleimide (EMA) binding test and cryohemolysis test for screening for hereditary spherocytosis (HS), and the flow cytometric osmotic fragility (FC OF) test was recently developed to replace the classic OF test. We evaluated the performance of the EM_A binding test, FC OF test, cryohemolysis test, and the hemoglobin (Hb)/mean corpuscular hemoglobin concentration (MCHC) ratio in the diagnosis of HS and assessed whether these tests reflect the clinical severity of HS. Methods: A total of 153 patients with anemia (33 with HS, 40 with autoimmune hemolytic anemia, 40 with anemia of chronic disease, and 40 with iron deficiency anemia [IDA]) and 140 healthy controls were enrolled, and the performance of the three tests was evaluated. Results: Both the EMA binding test (area under the curve LAUCJ, 0.996) and the FC OF test (AUC, 0.992) performed satisfactorily, but the cryohemolysis test (AUC, 0.723) performed significantly worse because offalse positivity in patients with IDA. The Hb/MCHC ratio (P <.001) was able to reflect the clinical severity of HS. Conclusions: Our results demonstrate that both the EMA binding and FC OF tests are useful as screening tests for the diagnosis of HS, but the cryohemolysis test has limited use due to its false positivity in IDA, with the Hb/MCHC ratio the most useful parameter for assessing the clinical severity of HS. | - |
| dc.format.extent | 11 | - |
| dc.language | 영어 | - |
| dc.language.iso | ENG | - |
| dc.publisher | OXFORD UNIV PRESS INC | - |
| dc.title | Comparison Study of the Eosin-5 '-Maleimide Binding Test, Flow Cytometric Osmotic Fragility Test, and Cryohemolysis Test in the Diagnosis of Hereditary Spherocytosis | - |
| dc.type | Article | - |
| dc.publisher.location | 미국 | - |
| dc.identifier.doi | 10.1309/AJCPO7V4OGXLIIPP | - |
| dc.identifier.scopusid | 2-s2.0-84921670126 | - |
| dc.identifier.wosid | 000342409600010 | - |
| dc.identifier.bibliographicCitation | AMERICAN JOURNAL OF CLINICAL PATHOLOGY, v.142, no.4, pp 474 - 484 | - |
| dc.citation.title | AMERICAN JOURNAL OF CLINICAL PATHOLOGY | - |
| dc.citation.volume | 142 | - |
| dc.citation.number | 4 | - |
| dc.citation.startPage | 474 | - |
| dc.citation.endPage | 484 | - |
| dc.type.docType | Article | - |
| dc.description.isOpenAccess | Y | - |
| dc.description.journalRegisteredClass | sci | - |
| dc.description.journalRegisteredClass | scie | - |
| dc.description.journalRegisteredClass | scopus | - |
| dc.relation.journalResearchArea | Pathology | - |
| dc.relation.journalWebOfScienceCategory | Pathology | - |
| dc.subject.keywordPlus | EOSIN-5-MALEIMIDE BINDING | - |
| dc.subject.keywordPlus | DIFFERENTIAL-DIAGNOSIS | - |
| dc.subject.keywordPlus | HEMOLYTIC-ANEMIA | - |
| dc.subject.keywordPlus | SCREENING-TEST | - |
| dc.subject.keywordPlus | GUIDELINES | - |
| dc.subject.keywordPlus | MANAGEMENT | - |
| dc.subject.keywordPlus | PROTEINS | - |
| dc.subject.keywordAuthor | Cryohemolysis test | - |
| dc.subject.keywordAuthor | EMA binding test | - |
| dc.subject.keywordAuthor | Flow cytometric osmotic fragility test | - |
| dc.subject.keywordAuthor | Hb/MCHC | - |
| dc.subject.keywordAuthor | Hereditary spherocytosis | - |
Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.
Gyeongsang National University Central Library, 501, Jinju-daero, Jinju-si, Gyeongsangnam-do, 52828, Republic of Korea+82-55-772-0532
COPYRIGHT 2022 GYEONGSANG NATIONAL UNIVERSITY LIBRARY. ALL RIGHTS RESERVED.
Certain data included herein are derived from the © Web of Science of Clarivate Analytics. All rights reserved.
You may not copy or re-distribute this material in whole or in part without the prior written consent of Clarivate Analytics.
