Cited 18 time in
Thermal and Daylighting Performance of Energy-Efficient Windows in Highly Glazed Residential Buildings: Case Study in Korea
| DC Field | Value | Language |
|---|---|---|
| dc.contributor.author | Cheong, Chang Heon | - |
| dc.contributor.author | Kim, Taeyeon | - |
| dc.contributor.author | Leigh, Seung-Bok | - |
| dc.date.accessioned | 2022-12-26T22:51:24Z | - |
| dc.date.available | 2022-12-26T22:51:24Z | - |
| dc.date.issued | 2014-10 | - |
| dc.identifier.issn | 2071-1050 | - |
| dc.identifier.uri | https://scholarworks.gnu.ac.kr/handle/sw.gnu/18721 | - |
| dc.description.abstract | Cooling load in highly glazed residential building can be excessively large due to uncontrolled solar energy entering the indoor space. This study focuses on the cooling load reduction and changes in the daylighting properties via the application of a double window system (DWS) with shading with various surface reflectivities in highly glazed residential buildings. Evaluation of thermal and daylighting performances is carried out using simulation tools. The reductions in cooling load and energy cost through the use of DWS are evaluated through a comparative simulation considering conventional windows: a single window and a double window. Three variables of window types, natural ventilation, and shading reflectivity are reflected in the study. According to our results, implementation of DWS reduced cooling load by 43%-61%. Electricity cost during the cooling period was reduced by a maximum of 24%. However, a shading device setting that prioritizes effective cooling load reduction can greatly decrease the daylighting factor and luminance level of indoor space. A DWS implementing shading device with highly reflective at all surfaces is appropriate option for the more comfortable thermal and visual environment, while a shading device with low reflectivity at rear of the surface can contribute an additional 4% cooling load reduction. | - |
| dc.format.extent | 23 | - |
| dc.language | 영어 | - |
| dc.language.iso | ENG | - |
| dc.publisher | MDPI | - |
| dc.title | Thermal and Daylighting Performance of Energy-Efficient Windows in Highly Glazed Residential Buildings: Case Study in Korea | - |
| dc.type | Article | - |
| dc.publisher.location | 스위스 | - |
| dc.identifier.doi | 10.3390/su6107311 | - |
| dc.identifier.scopusid | 2-s2.0-84910051269 | - |
| dc.identifier.wosid | 000344355700044 | - |
| dc.identifier.bibliographicCitation | SUSTAINABILITY, v.6, no.10, pp 7311 - 7333 | - |
| dc.citation.title | SUSTAINABILITY | - |
| dc.citation.volume | 6 | - |
| dc.citation.number | 10 | - |
| dc.citation.startPage | 7311 | - |
| dc.citation.endPage | 7333 | - |
| dc.type.docType | Article | - |
| dc.description.isOpenAccess | Y | - |
| dc.description.journalRegisteredClass | scie | - |
| dc.description.journalRegisteredClass | ssci | - |
| dc.description.journalRegisteredClass | scopus | - |
| dc.relation.journalResearchArea | Science & Technology - Other Topics | - |
| dc.relation.journalResearchArea | Environmental Sciences & Ecology | - |
| dc.relation.journalWebOfScienceCategory | Green & Sustainable Science & Technology | - |
| dc.relation.journalWebOfScienceCategory | Environmental Sciences | - |
| dc.relation.journalWebOfScienceCategory | Environmental Studies | - |
| dc.subject.keywordPlus | DOUBLE-SKIN FACADE | - |
| dc.subject.keywordPlus | NATURAL VENTILATION | - |
| dc.subject.keywordPlus | STRATEGIES | - |
| dc.subject.keywordPlus | SIMULATION | - |
| dc.subject.keywordPlus | SYSTEMS | - |
| dc.subject.keywordPlus | RATINGS | - |
| dc.subject.keywordPlus | HOT | - |
| dc.subject.keywordAuthor | double window system | - |
| dc.subject.keywordAuthor | residential building | - |
| dc.subject.keywordAuthor | cooling load | - |
| dc.subject.keywordAuthor | cooling energy consumption | - |
| dc.subject.keywordAuthor | visual environment | - |
Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.
Gyeongsang National University Central Library, 501, Jinju-daero, Jinju-si, Gyeongsangnam-do, 52828, Republic of Korea+82-55-772-0534
COPYRIGHT 2022 GYEONGSANG NATIONAL UNIVERSITY LIBRARY. ALL RIGHTS RESERVED.
Certain data included herein are derived from the © Web of Science of Clarivate Analytics. All rights reserved.
You may not copy or re-distribute this material in whole or in part without the prior written consent of Clarivate Analytics.