Detailed Information

Cited 7 time in webofscience Cited 7 time in scopus
Metadata Downloads

A case of phacolytic glaucoma with anterior lens capsule disruption identified by scanning electron microscopy

Full metadata record
DC Field Value Language
dc.contributor.authorYoo, Woong-Sun-
dc.contributor.authorKim, Byeong-Jae-
dc.contributor.authorChung, In-Young-
dc.contributor.authorSeo, Seong-Wook-
dc.contributor.authorYoo, Ji-Myong-
dc.contributor.authorKim, Seong-Jae-
dc.date.accessioned2022-12-26T22:49:58Z-
dc.date.available2022-12-26T22:49:58Z-
dc.date.issued2014-11-19-
dc.identifier.issn1471-2415-
dc.identifier.urihttps://scholarworks.gnu.ac.kr/handle/sw.gnu/18652-
dc.description.abstractBackground: Phacolytic glaucoma is induced by lens protein or macrophages that have leaked through a macroscopically intact anterior lens capsule. Here, we report a case of phacolytic glaucoma with anterior lens capsule disruptions visualized by scanning electron microscopy (SEM). Case presentation: A 71-year-old man was referred to our institute for increased intraocular pressure (IOP) in the right eye. Slit-lamp biomicroscopic examination revealed corneal edema, the presence of inflammatory cells and iridescent crystalline in the anterior chamber, and a hypermature cataract in the right eye. Despite treatment with topical glaucoma medication (0.15% brimonidine, 1% brinzolamide/0.5% timolol, and 0.03% bimatoprost) and systemic mannitol, his IOP remained uncontrolled. Light microscopy was used to examine the aqueous humor obtained via anterior chamber paracentesis and the anterior lens capsule obtained via intracapsular cataract extraction (ICCE), which revealed that the anterior lens capsule was intact. However, SEM revealed full-thickness disruptions in the anterior lens. Conclusion: This is the first reported case of phacolytic glaucoma with disruptions of the anterior lens capsule confirmed by SEM.-
dc.language영어-
dc.language.isoENG-
dc.publisherBIOMED CENTRAL LTD-
dc.titleA case of phacolytic glaucoma with anterior lens capsule disruption identified by scanning electron microscopy-
dc.typeArticle-
dc.publisher.location영국-
dc.identifier.doi10.1186/1471-2415-14-133-
dc.identifier.scopusid2-s2.0-84964313269-
dc.identifier.wosid000348863900001-
dc.identifier.bibliographicCitationBMC Ophthalmology, v.14-
dc.citation.titleBMC Ophthalmology-
dc.citation.volume14-
dc.type.docTypeArticle-
dc.description.isOpenAccessY-
dc.description.journalRegisteredClassscie-
dc.description.journalRegisteredClassscopus-
dc.relation.journalResearchAreaOphthalmology-
dc.relation.journalWebOfScienceCategoryOphthalmology-
dc.subject.keywordAuthorPhacolytic glaucoma-
dc.subject.keywordAuthorLens capsule-
dc.subject.keywordAuthorScanning electron microscopy (SEM)-
Files in This Item
There are no files associated with this item.
Appears in
Collections
College of Medicine > Department of Medicine > Journal Articles