Cited 9 time in
Combination effects of tissue heterogeneity and geometric targeting error in stereotactic body radiotherapy for lung cancer using CyberKnife
| DC Field | Value | Language |
|---|---|---|
| dc.contributor.author | Kang, Ki Mun | - |
| dc.contributor.author | Jeong, Bae Kwon | - |
| dc.contributor.author | Choi, Hoon-Sik | - |
| dc.contributor.author | Yoo, Seung Hoon | - |
| dc.contributor.author | Hwang, Ui-Jung | - |
| dc.contributor.author | Lim, Young Kyung | - |
| dc.contributor.author | Jeong, Hojin | - |
| dc.date.accessioned | 2022-12-26T22:47:31Z | - |
| dc.date.available | 2022-12-26T22:47:31Z | - |
| dc.date.issued | 2015 | - |
| dc.identifier.issn | 1526-9914 | - |
| dc.identifier.uri | https://scholarworks.gnu.ac.kr/handle/sw.gnu/18521 | - |
| dc.description.abstract | We have investigated the combined effect of tissue heterogeneity and its variation associated with geometric error in stereotactic body radiotherapy (SBRT) for lung cancer. The treatment plans for eight lung cancer patients were calculated using effective path length (EPL) correction and Monte Carlo (MC) algorithms, with both having the same beam configuration for each patient. These two kinds of plans for individual patients were then subsequently recalculated with adding systematic and random geometric errors. In the ordinary treatment plans calculated with no geometric offset, the EPL calculations, compared with the MC calculations, largely overestimated the doses to PTV by similar to 21%, whereas the overestimation were markedly lower in GTV by similar to 12% due to relatively higher density of GTV than of PTV. When recalculating the plans for individual patients with assigning the systematic and random geometric errors, no significant changes in the relative dose distribution, except for overall shift, were observed in the EPL calculations, whereas largely altered in the MC calculations with a consistent increase in dose to GTV. Considering the better accuracy of MC than EPL algorithms, the present results demonstrated the strong coupling of tissue heterogeneity and geometric error, thereby emphasizing the essential need for simultaneous correction for tissue heterogeneity and geometric targeting error in SBRT of lung cancer. | - |
| dc.format.extent | 12 | - |
| dc.language | 영어 | - |
| dc.language.iso | ENG | - |
| dc.publisher | WILEY | - |
| dc.title | Combination effects of tissue heterogeneity and geometric targeting error in stereotactic body radiotherapy for lung cancer using CyberKnife | - |
| dc.type | Article | - |
| dc.publisher.location | 미국 | - |
| dc.identifier.doi | 10.1120/jacmp.v16i5.5397 | - |
| dc.identifier.scopusid | 2-s2.0-84946921330 | - |
| dc.identifier.wosid | 000368340900017 | - |
| dc.identifier.bibliographicCitation | JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, v.16, no.5, pp 193 - 204 | - |
| dc.citation.title | JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS | - |
| dc.citation.volume | 16 | - |
| dc.citation.number | 5 | - |
| dc.citation.startPage | 193 | - |
| dc.citation.endPage | 204 | - |
| dc.type.docType | Article | - |
| dc.description.isOpenAccess | Y | - |
| dc.description.journalRegisteredClass | scie | - |
| dc.description.journalRegisteredClass | scopus | - |
| dc.relation.journalResearchArea | Radiology, Nuclear Medicine & Medical Imaging | - |
| dc.relation.journalWebOfScienceCategory | Radiology, Nuclear Medicine & Medical Imaging | - |
| dc.subject.keywordPlus | MONTE-CARLO | - |
| dc.subject.keywordPlus | DOSE CALCULATION | - |
| dc.subject.keywordPlus | STAGE-I | - |
| dc.subject.keywordPlus | RADIATION-THERAPY | - |
| dc.subject.keywordPlus | INHOMOGENEITY CORRECTIONS | - |
| dc.subject.keywordPlus | ALGORITHMS | - |
| dc.subject.keywordPlus | TRACKING | - |
| dc.subject.keywordPlus | OPTIMIZATION | - |
| dc.subject.keywordPlus | ACCURACY | - |
| dc.subject.keywordPlus | SYSTEM | - |
| dc.subject.keywordAuthor | stereotactic body radiotherapy | - |
| dc.subject.keywordAuthor | SBRT | - |
| dc.subject.keywordAuthor | lung cancer | - |
| dc.subject.keywordAuthor | effective path length correction | - |
| dc.subject.keywordAuthor | Monte Carlo | - |
| dc.subject.keywordAuthor | tissue heterogeneity | - |
| dc.subject.keywordAuthor | geometric error | - |
Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.
Gyeongsang National University Central Library, 501, Jinju-daero, Jinju-si, Gyeongsangnam-do, 52828, Republic of Korea+82-55-772-0532
COPYRIGHT 2022 GYEONGSANG NATIONAL UNIVERSITY LIBRARY. ALL RIGHTS RESERVED.
Certain data included herein are derived from the © Web of Science of Clarivate Analytics. All rights reserved.
You may not copy or re-distribute this material in whole or in part without the prior written consent of Clarivate Analytics.
