Cited 0 time in
상온 수압반복시험 시 Type 3 복합재용기 내 공기층의 온도변화
| DC Field | Value | Language |
|---|---|---|
| dc.contributor.author | 조성민 | - |
| dc.contributor.author | 김광석 | - |
| dc.contributor.author | 김창종 | - |
| dc.contributor.author | 유근준 | - |
| dc.contributor.author | 이연재 | - |
| dc.contributor.author | 조윤성 | - |
| dc.contributor.author | 류성기 | - |
| dc.date.accessioned | 2022-12-26T22:16:25Z | - |
| dc.date.available | 2022-12-26T22:16:25Z | - |
| dc.date.issued | 2015 | - |
| dc.identifier.issn | 1598-6721 | - |
| dc.identifier.issn | 2288-0771 | - |
| dc.identifier.uri | https://scholarworks.gnu.ac.kr/handle/sw.gnu/17870 | - |
| dc.description.abstract | This research aims to increase the reliability and reproducibility of the ambient cycling test by properly making corrections to the test procedure. The vessel (106 L) is initially filled with 70 L of water and horizontally placed on a balance. The pressure range inside the vessel varies from 2.5 to 25.9 MPa at the frequency of 6 cycles per minute. After reviewing the results, there was a temperature difference of approximately 10 °C between the air pocket and the water, and the upper part of the liner faced a repeated temperature change of 40 °C. It is possible for the aluminum liner of the composite vessel to be damaged by such a sharp change in temperature. Additionally, as a result, no pass having anything to do with the purpose of the test would occur. Therefore, it is suggested that the air pocket be completely removed. | - |
| dc.format.extent | 6 | - |
| dc.language | 한국어 | - |
| dc.language.iso | KOR | - |
| dc.publisher | 한국기계가공학회 | - |
| dc.title | 상온 수압반복시험 시 Type 3 복합재용기 내 공기층의 온도변화 | - |
| dc.title.alternative | Temperature Variations of Air Pocket in Type-3 Composite Vessel during Ambient Hydraulic Cycling Test | - |
| dc.type | Article | - |
| dc.publisher.location | 대한민국 | - |
| dc.identifier.doi | 10.14775/ksmpe.2015.14.4.134 | - |
| dc.identifier.bibliographicCitation | 한국기계가공학회지, v.14, no.5, pp 120 - 125 | - |
| dc.citation.title | 한국기계가공학회지 | - |
| dc.citation.volume | 14 | - |
| dc.citation.number | 5 | - |
| dc.citation.startPage | 120 | - |
| dc.citation.endPage | 125 | - |
| dc.identifier.kciid | ART002047037 | - |
| dc.description.isOpenAccess | Y | - |
| dc.description.journalRegisteredClass | kci | - |
| dc.subject.keywordAuthor | Ambient Hydraulic Cycling Test(상온수압반복시험) | - |
| dc.subject.keywordAuthor | Type3 Composite Vessel(타입3복합재용기) | - |
| dc.subject.keywordAuthor | Internal Temperature Variations(내부온도변화) | - |
Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.
Gyeongsang National University Central Library, 501, Jinju-daero, Jinju-si, Gyeongsangnam-do, 52828, Republic of Korea+82-55-772-0532
COPYRIGHT 2022 GYEONGSANG NATIONAL UNIVERSITY LIBRARY. ALL RIGHTS RESERVED.
Certain data included herein are derived from the © Web of Science of Clarivate Analytics. All rights reserved.
You may not copy or re-distribute this material in whole or in part without the prior written consent of Clarivate Analytics.