| dc.description.abstract | This study focuses on simulation technology in the injection molding process for plastic optic lenses. The CAE program 3D TIMON was used to predict retardation, flow patterns and warpage deformation. The results were compared to the results of optic lenses as measured using the WPA-100 retardation measurement device with injection molding CAE for retardation predictions. According to the analysis and measured results, the distributions of retardation between the CAE results and the measurement results were similar. It was also confirmed that varying the injection speed had an effect on the injection pressure, warpage deformation and retardation distribution. As the injection speed increases, the injection pressure also increases and warpage deformation decreases. However, as the injection speed increases, the retardation distribution deteriorates. | - |
| dc.format.extent | 6 | - |
| dc.language | 한국어 | - |
| dc.language.iso | KOR | - |
| dc.publisher | 한국기계가공학회 | - |
| dc.title | 사출속도 변화에 따른 플라스틱 광학렌즈의 위상차 해석 | - |
| dc.title.alternative | Retardation Analysis of Plastic Optic Lens according to Injection Speed Variation | - |
| dc.type | Article | - |
| dc.publisher.location | 대한민국 | - |
| dc.identifier.doi | 10.14775/ksmpe.2015.14.1.093 | - |
| dc.identifier.bibliographicCitation | 한국기계가공학회지, v.14, no.2, pp 93 - 98 | - |
| dc.citation.title | 한국기계가공학회지 | - |
| dc.citation.volume | 14 | - |
| dc.citation.number | 2 | - |
| dc.citation.startPage | 93 | - |
| dc.citation.endPage | 98 | - |
| dc.identifier.kciid | ART001988336 | - |
| dc.description.isOpenAccess | N | - |
| dc.description.journalRegisteredClass | kci | - |
| dc.subject.keywordAuthor | Retardation(위상차) | - |
| dc.subject.keywordAuthor | Birefringence(복굴절) | - |
| dc.subject.keywordAuthor | Phone Camera(폰 카메라) | - |
| dc.subject.keywordAuthor | Plastic Optic lens(플라스틱 광학 렌즈) | - |
| dc.subject.keywordAuthor | Residual Stress(잔류 응력) | - |
Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.
Gyeongsang National University Central Library, 501, Jinju-daero, Jinju-si, Gyeongsangnam-do, 52828, Republic of Korea+82-55-772-0532
COPYRIGHT 2022 GYEONGSANG NATIONAL UNIVERSITY LIBRARY. ALL RIGHTS RESERVED.
Certain data included herein are derived from the © Web of Science of Clarivate Analytics. All rights reserved.
You may not copy or re-distribute this material in whole or in part without the prior written consent of Clarivate Analytics.