Cited 0 time in
Multi-support excitation shaking table test of a base-isolated steel cable-stayed bridge
| DC Field | Value | Language |
|---|---|---|
| dc.contributor.author | 김성도 | - |
| dc.contributor.author | 안진희 | - |
| dc.contributor.author | 공영이 | - |
| dc.contributor.author | 최형석 | - |
| dc.contributor.author | 정진환 | - |
| dc.date.accessioned | 2022-12-26T22:01:59Z | - |
| dc.date.available | 2022-12-26T22:01:59Z | - |
| dc.date.issued | 2015 | - |
| dc.identifier.issn | 1226-525X | - |
| dc.identifier.issn | 2234-1099 | - |
| dc.identifier.uri | https://scholarworks.gnu.ac.kr/handle/sw.gnu/17626 | - |
| dc.description.abstract | A series of tests was conducted for full-scale single-pylon asymmetric cable-stayed bridges using a system of multiple shaking tables. The 2-span bridge length was 28 m, and the pylon height was 10.2 m. 4 different base conditions were considered: the fixed condition, RB (rubber bearings), LRB (lead rubber bearings), and HDRB (high damping rubber bearings). Based on investigation of the seismic response, the accelerations and displacements in the axial direction of the isolated bridge were increased compared to non-isolated case. However, the strain of the pylon was decreased, because the major mode of the structure was changed to translation for the axial direction due to the dynamic mass. The response of the cable bridge could differ from the desired response according to the locations and characteristics of the seismic isolator. Therefore, caution is required in the design and prediction in regard to the location and behavior of the seismic isolator. | - |
| dc.format.extent | 11 | - |
| dc.language | 영어 | - |
| dc.language.iso | ENG | - |
| dc.publisher | 한국지진공학회 | - |
| dc.title | Multi-support excitation shaking table test of a base-isolated steel cable-stayed bridge | - |
| dc.title.alternative | Multi-support excitation shaking table test of a base-isolated steel cable-stayed bridge | - |
| dc.type | Article | - |
| dc.publisher.location | 대한민국 | - |
| dc.identifier.bibliographicCitation | 한국지진공학회논문집, v.19, no.4, pp 161 - 171 | - |
| dc.citation.title | 한국지진공학회논문집 | - |
| dc.citation.volume | 19 | - |
| dc.citation.number | 4 | - |
| dc.citation.startPage | 161 | - |
| dc.citation.endPage | 171 | - |
| dc.identifier.kciid | ART002004907 | - |
| dc.description.isOpenAccess | N | - |
| dc.description.journalRegisteredClass | kci | - |
| dc.subject.keywordAuthor | Steel cable-stayed bridge | - |
| dc.subject.keywordAuthor | Multi-support excitation shaking table | - |
| dc.subject.keywordAuthor | Dynamic response | - |
| dc.subject.keywordAuthor | Base-isolation condition. | - |
Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.
Gyeongsang National University Central Library, 501, Jinju-daero, Jinju-si, Gyeongsangnam-do, 52828, Republic of Korea+82-55-772-0532
COPYRIGHT 2022 GYEONGSANG NATIONAL UNIVERSITY LIBRARY. ALL RIGHTS RESERVED.
Certain data included herein are derived from the © Web of Science of Clarivate Analytics. All rights reserved.
You may not copy or re-distribute this material in whole or in part without the prior written consent of Clarivate Analytics.