Detailed Information

Cited 11 time in webofscience Cited 16 time in scopus
Metadata Downloads

The uniform chest compression depth of 50 mm or greater recommended by current guidelines is not appropriate for all adults

Full metadata record
DC Field Value Language
dc.contributor.authorLee, Soo Hoon-
dc.contributor.authorKim, Dong Hoon-
dc.contributor.authorKang, Tae-Sin-
dc.contributor.authorKang, Changwoo-
dc.contributor.authorJeong, Jin Hee-
dc.contributor.authorKim, Seong Chun-
dc.contributor.authorKim, Dong Seob-
dc.date.accessioned2022-12-26T21:34:02Z-
dc.date.available2022-12-26T21:34:02Z-
dc.date.issued2015-08-
dc.identifier.issn0735-6757-
dc.identifier.issn1532-8171-
dc.identifier.urihttps://scholarworks.gnu.ac.kr/handle/sw.gnu/17108-
dc.description.abstractObjective: This study was conducted to evaluate the appropriateness of the chest compression (CC) depth recommended in the current guidelines and simulated external CCs, and to characterize the optimal CC depth for an adult by body mass index (BMI). Methods: Adult patients who underwent chest computed tomography as a screening test for latent pulmonary diseases in the health care center were enrolled in this study. We calculated the internal anteroposterior (AP) diameter (IAPD) and external AP diameter (EAPD) of the chest across BMIs (<18.50, 18.50-24.99, 25.00-29.99, and >= 30.00 kg/m(2)) for simulated CC depth. We also calculated the residual chest depths less than 20 mm for simulated CC depth. Results: There was a statistically significant difference in the chest EAPD and IAPD measured at the lower half of the sternum for each BMI groups (EAPD: R-2 = 0.638, P < .001; IAPD: R-2 = 0.297, P < .001). For one-half external AP CC, 100% of the patients, regardless of BMI, had a calculated residual internal chest depth less than 20 mm. For one-fourth external AP CC, no patients had a calculated residual internal chest depth less than 20 mm. For one-third external AP CC, only 6.48% of the patients had a calculated residual internal chest depth less than 20 mm. Conclusions: It is not appropriate that the current CC depth (>= 50 mm), expressed only as absolute measurement without a fraction of the depth of the chest, is applied uniformly in all adults. In addition, in terms of safety and efficacy, simulated CC targeting approximately between one-third and one-fourth EAPD CC depth might be appropriate. (C) 2015 Elsevier Inc. All rights reserved.-
dc.format.extent5-
dc.language영어-
dc.language.isoENG-
dc.publisherW B SAUNDERS CO-ELSEVIER INC-
dc.titleThe uniform chest compression depth of 50 mm or greater recommended by current guidelines is not appropriate for all adults-
dc.typeArticle-
dc.publisher.location미국-
dc.identifier.doi10.1016/j.ajem.2015.04.034-
dc.identifier.scopusid2-s2.0-84932200051-
dc.identifier.wosid000356604000009-
dc.identifier.bibliographicCitationAMERICAN JOURNAL OF EMERGENCY MEDICINE, v.33, no.8, pp 1037 - 1041-
dc.citation.titleAMERICAN JOURNAL OF EMERGENCY MEDICINE-
dc.citation.volume33-
dc.citation.number8-
dc.citation.startPage1037-
dc.citation.endPage1041-
dc.type.docTypeArticle-
dc.description.isOpenAccessN-
dc.description.journalRegisteredClassscie-
dc.description.journalRegisteredClassscopus-
dc.relation.journalResearchAreaEmergency Medicine-
dc.relation.journalWebOfScienceCategoryEmergency Medicine-
dc.subject.keywordPlusHOSPITAL CARDIAC-ARREST-
dc.subject.keywordPlusIMPULSE CARDIOPULMONARY-RESUSCITATION-
dc.subject.keywordPlusVENTRICULAR WALL THICKNESS-
dc.subject.keywordPlusECHOCARDIOGRAPHIC MEASUREMENT-
dc.subject.keywordPlusLIVER-INJURY-
dc.subject.keywordPlusQUALITY-
dc.subject.keywordPlusCHILDREN-
dc.subject.keywordPlusBLOOD-
dc.subject.keywordPlusMODEL-
dc.subject.keywordPlusNEED-
Files in This Item
There are no files associated with this item.
Appears in
Collections
College of Medicine > Department of Medicine > Journal Articles

qrcode

Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.

Altmetrics

Total Views & Downloads

BROWSE