Cited 16 time in
The uniform chest compression depth of 50 mm or greater recommended by current guidelines is not appropriate for all adults
| DC Field | Value | Language |
|---|---|---|
| dc.contributor.author | Lee, Soo Hoon | - |
| dc.contributor.author | Kim, Dong Hoon | - |
| dc.contributor.author | Kang, Tae-Sin | - |
| dc.contributor.author | Kang, Changwoo | - |
| dc.contributor.author | Jeong, Jin Hee | - |
| dc.contributor.author | Kim, Seong Chun | - |
| dc.contributor.author | Kim, Dong Seob | - |
| dc.date.accessioned | 2022-12-26T21:34:02Z | - |
| dc.date.available | 2022-12-26T21:34:02Z | - |
| dc.date.issued | 2015-08 | - |
| dc.identifier.issn | 0735-6757 | - |
| dc.identifier.issn | 1532-8171 | - |
| dc.identifier.uri | https://scholarworks.gnu.ac.kr/handle/sw.gnu/17108 | - |
| dc.description.abstract | Objective: This study was conducted to evaluate the appropriateness of the chest compression (CC) depth recommended in the current guidelines and simulated external CCs, and to characterize the optimal CC depth for an adult by body mass index (BMI). Methods: Adult patients who underwent chest computed tomography as a screening test for latent pulmonary diseases in the health care center were enrolled in this study. We calculated the internal anteroposterior (AP) diameter (IAPD) and external AP diameter (EAPD) of the chest across BMIs (<18.50, 18.50-24.99, 25.00-29.99, and >= 30.00 kg/m(2)) for simulated CC depth. We also calculated the residual chest depths less than 20 mm for simulated CC depth. Results: There was a statistically significant difference in the chest EAPD and IAPD measured at the lower half of the sternum for each BMI groups (EAPD: R-2 = 0.638, P < .001; IAPD: R-2 = 0.297, P < .001). For one-half external AP CC, 100% of the patients, regardless of BMI, had a calculated residual internal chest depth less than 20 mm. For one-fourth external AP CC, no patients had a calculated residual internal chest depth less than 20 mm. For one-third external AP CC, only 6.48% of the patients had a calculated residual internal chest depth less than 20 mm. Conclusions: It is not appropriate that the current CC depth (>= 50 mm), expressed only as absolute measurement without a fraction of the depth of the chest, is applied uniformly in all adults. In addition, in terms of safety and efficacy, simulated CC targeting approximately between one-third and one-fourth EAPD CC depth might be appropriate. (C) 2015 Elsevier Inc. All rights reserved. | - |
| dc.format.extent | 5 | - |
| dc.language | 영어 | - |
| dc.language.iso | ENG | - |
| dc.publisher | W B SAUNDERS CO-ELSEVIER INC | - |
| dc.title | The uniform chest compression depth of 50 mm or greater recommended by current guidelines is not appropriate for all adults | - |
| dc.type | Article | - |
| dc.publisher.location | 미국 | - |
| dc.identifier.doi | 10.1016/j.ajem.2015.04.034 | - |
| dc.identifier.scopusid | 2-s2.0-84932200051 | - |
| dc.identifier.wosid | 000356604000009 | - |
| dc.identifier.bibliographicCitation | AMERICAN JOURNAL OF EMERGENCY MEDICINE, v.33, no.8, pp 1037 - 1041 | - |
| dc.citation.title | AMERICAN JOURNAL OF EMERGENCY MEDICINE | - |
| dc.citation.volume | 33 | - |
| dc.citation.number | 8 | - |
| dc.citation.startPage | 1037 | - |
| dc.citation.endPage | 1041 | - |
| dc.type.docType | Article | - |
| dc.description.isOpenAccess | N | - |
| dc.description.journalRegisteredClass | scie | - |
| dc.description.journalRegisteredClass | scopus | - |
| dc.relation.journalResearchArea | Emergency Medicine | - |
| dc.relation.journalWebOfScienceCategory | Emergency Medicine | - |
| dc.subject.keywordPlus | HOSPITAL CARDIAC-ARREST | - |
| dc.subject.keywordPlus | IMPULSE CARDIOPULMONARY-RESUSCITATION | - |
| dc.subject.keywordPlus | VENTRICULAR WALL THICKNESS | - |
| dc.subject.keywordPlus | ECHOCARDIOGRAPHIC MEASUREMENT | - |
| dc.subject.keywordPlus | LIVER-INJURY | - |
| dc.subject.keywordPlus | QUALITY | - |
| dc.subject.keywordPlus | CHILDREN | - |
| dc.subject.keywordPlus | BLOOD | - |
| dc.subject.keywordPlus | MODEL | - |
| dc.subject.keywordPlus | NEED | - |
Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.
Gyeongsang National University Central Library, 501, Jinju-daero, Jinju-si, Gyeongsangnam-do, 52828, Republic of Korea+82-55-772-0532
COPYRIGHT 2022 GYEONGSANG NATIONAL UNIVERSITY LIBRARY. ALL RIGHTS RESERVED.
Certain data included herein are derived from the © Web of Science of Clarivate Analytics. All rights reserved.
You may not copy or re-distribute this material in whole or in part without the prior written consent of Clarivate Analytics.
