Detailed Information

Cited 3 time in webofscience Cited 4 time in scopus
Metadata Downloads

Long-Term Outcome of Corneal and Anterior Chamber Angle Parameters after Combined Laser Iridotomy and Iridoplasty Using Dual Scheimpflug Analyzer: 1 Year Results

Full metadata record
DC Field Value Language
dc.contributor.authorCho, Hyun-kyung-
dc.contributor.authorChoae, Wooseok-
dc.date.accessioned2022-12-26T07:40:29Z-
dc.date.available2022-12-26T07:40:29Z-
dc.date.issued2022-02-
dc.identifier.issn2077-0383-
dc.identifier.urihttps://scholarworks.gnu.ac.kr/handle/sw.gnu/1689-
dc.description.abstractBackground: To investigate the outcomes of corneal and anterior chamber angle (ACA) parameters after laser iridotomy (LI) combined with peripheral iridoplasty (PI) using dual Scheimpflug analyzer in the long term. Methods: Fifty-eight eyes (58 subjects) with shallow AC were included in this prospective cohort study. Images of the Dual Scheimpflug analyzer were obtained before, 1 week, and 1 year after LI and PI. Pachymetry from three zones (central, middle, and peripheral), corneal aberration, and spherical equivalent (SE) were acquired. AC depth (ACD), AC volume (ACV), ACA from four quadrants, and intraocular pressure (IOP) were also obtained. For comparison of the results, the linear mixed-effects model was employed. Results: ACD significantly increased from 2.09 +/- 0.25 mm to 2.10 +/- 0.23 mm at 1 year after laser (all p < 0.05). ACV and ACA increased significantly after laser at 1 year (all p < 0.05). IOP significantly decreased from 15.97 +/- 4.20 mmHg to 13.73 +/- 2.63 mmHg at 1 year (all p < 0.0001). No significant changes were found in the coma, trefoil, total corneal aberration, pachymetry from three zones, corneal volume, central corneal thickness, and SE after LI and PI until 1 year (all p > 0.05). Conclusions: LI plus PI ameliorated parameters of ACA efficiently and significantly reduced IOP in eyes with shallow AC until 1 year of long-term follow-up. However, parameters of the cornea and SE were not influenced by LI with PI until after 1 year.-
dc.language영어-
dc.language.isoENG-
dc.publisherMDPI AG-
dc.titleLong-Term Outcome of Corneal and Anterior Chamber Angle Parameters after Combined Laser Iridotomy and Iridoplasty Using Dual Scheimpflug Analyzer: 1 Year Results-
dc.typeArticle-
dc.publisher.location스위스-
dc.identifier.doi10.3390/jcm11030813-
dc.identifier.scopusid2-s2.0-85123950925-
dc.identifier.wosid000757387200001-
dc.identifier.bibliographicCitationJournal of Clinical Medicine, v.11, no.3-
dc.citation.titleJournal of Clinical Medicine-
dc.citation.volume11-
dc.citation.number3-
dc.type.docTypeArticle-
dc.description.isOpenAccessY-
dc.description.journalRegisteredClassscie-
dc.description.journalRegisteredClassscopus-
dc.relation.journalResearchAreaGeneral & Internal Medicine-
dc.relation.journalWebOfScienceCategoryMedicine, General & Internal-
dc.subject.keywordPlusIRIDOTRABECULAR CONTACT INDEX-
dc.subject.keywordPlusENDOTHELIAL-CELL DENSITY-
dc.subject.keywordPlusPERIPHERAL IRIDOTOMY-
dc.subject.keywordPlusCLOSURE GLAUCOMA-
dc.subject.keywordPlusLONGITUDINAL CHANGES-
dc.subject.keywordPlusPOPULATION-
dc.subject.keywordPlusARGON-
dc.subject.keywordPlusACCOMMODATION-
dc.subject.keywordPlusPREVALENCE-
dc.subject.keywordPlusSUSPECTS-
dc.subject.keywordAuthoranterior chamber angle-
dc.subject.keywordAuthorlaser iridoplasty-
dc.subject.keywordAuthorlaser iridotomy-
dc.subject.keywordAuthorprimary angle-closure-
dc.subject.keywordAuthordual Scheimpflug analyzer-
Files in This Item
There are no files associated with this item.
Appears in
Collections
College of Medicine > Department of Medicine > Journal Articles

qrcode

Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.

Related Researcher

Researcher Cho, Hyun Kyung photo

Cho, Hyun Kyung
의과대학 (의학과)
Read more

Altmetrics

Total Views & Downloads

BROWSE