Cited 32 time in
Optimisation, evaluation and application of asymmetrical flow field-flow fractionation with single particle inductively coupled plasma mass spectrometry (SP-ICP-MS) to characterise silver nanoparticles in environmental media
| DC Field | Value | Language |
|---|---|---|
| dc.contributor.author | Lee, W.-C. | - |
| dc.contributor.author | Lee, B.-T. | - |
| dc.contributor.author | Lee, S. | - |
| dc.contributor.author | Hwang, Y.S. | - |
| dc.contributor.author | Jo, E. | - |
| dc.contributor.author | Eom, I.-C. | - |
| dc.contributor.author | Lee, S.-W. | - |
| dc.contributor.author | Kim, S.-O. | - |
| dc.date.accessioned | 2022-12-26T21:17:55Z | - |
| dc.date.available | 2022-12-26T21:17:55Z | - |
| dc.date.issued | 2016 | - |
| dc.identifier.issn | 0026-265X | - |
| dc.identifier.issn | 1095-9149 | - |
| dc.identifier.uri | https://scholarworks.gnu.ac.kr/handle/sw.gnu/16761 | - |
| dc.description.abstract | The consumption of nanomaterials has been steadily increasing in various industrial and commercial sectors. For engineered nanoparticles (ENPs), the development of appropriate methods for separating, characterising and quantifying is a prerequisite for their risk assessment and evaluation in terms of environmental exposure. Asymmetrical flow field-flow fractionation (AF4) coupled with single particle inductively coupled plasma mass spectrometry (AF4/SP-ICP-MS) is considered to be a valuable tool able to achieve these goals. Studies on the evaluation of AF4 performance, however, are lacking because most previous research has considered the separation and quantification of ENPs separately without verifying the resolution and recovery regarding AF4. As a result, a biased and erroneous interpretation of AF4 capability could result. Moreover, focus has been on the characterisation of individual ENPs, although various properties of ENPs, such as the type of capping materials, greatly affect the performance of AF4. For this reason, this study focused on the optimisation of AF4 operational conditions by considering the effects of coating materials to efficiently separate silver NPs (AgNPs). In addition, the overall performance of AF4 was evaluated by comparing results obtained from various detectors, such as ultraviolet-visible spectroscopy (UV?VIS), multi-angle light scattering (MALS), dynamic light scattering (DLS), transmission electron microscopy (TEM) and SP-ICP-MS. A methodology was proposed to correct the erroneous and biased interpretation of AF4 performance in terms of signal characteristics, resolution and recovery. Then, the optimised method was applied to real aqueous samples to verify its practicality on environmental media. ? 2016 Elsevier B.V. | - |
| dc.format.extent | 12 | - |
| dc.language | 영어 | - |
| dc.language.iso | ENG | - |
| dc.publisher | Elsevier Inc. | - |
| dc.title | Optimisation, evaluation and application of asymmetrical flow field-flow fractionation with single particle inductively coupled plasma mass spectrometry (SP-ICP-MS) to characterise silver nanoparticles in environmental media | - |
| dc.type | Article | - |
| dc.publisher.location | 네델란드 | - |
| dc.identifier.doi | 10.1016/j.microc.2016.06.030 | - |
| dc.identifier.scopusid | 2-s2.0-84977638835 | - |
| dc.identifier.bibliographicCitation | Microchemical Journal, v.129, pp 219 - 230 | - |
| dc.citation.title | Microchemical Journal | - |
| dc.citation.volume | 129 | - |
| dc.citation.startPage | 219 | - |
| dc.citation.endPage | 230 | - |
| dc.type.docType | Article | - |
| dc.description.isOpenAccess | N | - |
| dc.description.journalRegisteredClass | sci | - |
| dc.description.journalRegisteredClass | scie | - |
| dc.description.journalRegisteredClass | scopus | - |
| dc.subject.keywordAuthor | Application | - |
| dc.subject.keywordAuthor | Asymmetrical flow field-flow fractionation | - |
| dc.subject.keywordAuthor | Optimisation of operating conditions | - |
| dc.subject.keywordAuthor | Performance evaluation | - |
| dc.subject.keywordAuthor | Silver nanoparticles | - |
| dc.subject.keywordAuthor | Single particle inductively coupled plasma mass spectrometry | - |
Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.
Gyeongsang National University Central Library, 501, Jinju-daero, Jinju-si, Gyeongsangnam-do, 52828, Republic of Korea+82-55-772-0532
COPYRIGHT 2022 GYEONGSANG NATIONAL UNIVERSITY LIBRARY. ALL RIGHTS RESERVED.
Certain data included herein are derived from the © Web of Science of Clarivate Analytics. All rights reserved.
You may not copy or re-distribute this material in whole or in part without the prior written consent of Clarivate Analytics.
