Cited 4 time in
Experimental Study on a Fixed Type Natural Ventilator
| DC Field | Value | Language |
|---|---|---|
| dc.contributor.author | Kim, Y.S. | - |
| dc.contributor.author | Chung, H. | - |
| dc.contributor.author | Jeong, H. | - |
| dc.contributor.author | Song, S.-K. | - |
| dc.contributor.author | Yi, C. | - |
| dc.contributor.author | Choi, S.-H. | - |
| dc.date.accessioned | 2022-12-26T21:17:44Z | - |
| dc.date.available | 2022-12-26T21:17:44Z | - |
| dc.date.issued | 2016 | - |
| dc.identifier.issn | 2010-1325 | - |
| dc.identifier.issn | 2010-1333 | - |
| dc.identifier.uri | https://scholarworks.gnu.ac.kr/handle/sw.gnu/16747 | - |
| dc.description.abstract | Ventilation is the intentional air supply to a closed space from the outside, which is essential for the sake of a comfortable environment and the health of human beings. In recent, with the wide spread of renewable energy, much attention has been paid to the natural ventilation. The natural ventilator is classified into a fixed type, a venturi type and a wind turbine type. In this study, the ventilation rates of the fixed type ventilator were experimentally investigated by changing the wind velocity. Additionally, the condition of a backflow was also examined. According to the experimental results, the ventilated air flow strongly depended on the outside wind velocity and also on the intake opening area. In the reverse flow test, it was confirmed that the reverse flow into the ventilator occurred if the wind velocity was under a certain threshold value. Furthermore, the reverse flow phenomenon was more severe when an obstacle is located in the downstream of a ventilator. ? 2016 World Scientific Publishing Company. | - |
| dc.language | 영어 | - |
| dc.language.iso | ENG | - |
| dc.publisher | World Scientific Publishing Co. Pte Ltd | - |
| dc.title | Experimental Study on a Fixed Type Natural Ventilator | - |
| dc.type | Article | - |
| dc.publisher.location | 대한민국 | - |
| dc.identifier.doi | 10.1142/S2010132516500164 | - |
| dc.identifier.scopusid | 2-s2.0-84981249359 | - |
| dc.identifier.bibliographicCitation | International Journal of Air-Conditioning and Refrigeration, v.24, no.3 | - |
| dc.citation.title | International Journal of Air-Conditioning and Refrigeration | - |
| dc.citation.volume | 24 | - |
| dc.citation.number | 3 | - |
| dc.type.docType | Article | - |
| dc.identifier.kciid | ART002151393 | - |
| dc.description.isOpenAccess | N | - |
| dc.description.journalRegisteredClass | scopus | - |
| dc.description.journalRegisteredClass | esci | - |
| dc.description.journalRegisteredClass | kci | - |
| dc.subject.keywordAuthor | Area ratio | - |
| dc.subject.keywordAuthor | fixed type ventilator | - |
| dc.subject.keywordAuthor | natural ventilation | - |
| dc.subject.keywordAuthor | reverse flow | - |
| dc.subject.keywordAuthor | wind velocity | - |
Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.
Gyeongsang National University Central Library, 501, Jinju-daero, Jinju-si, Gyeongsangnam-do, 52828, Republic of Korea+82-55-772-0532
COPYRIGHT 2022 GYEONGSANG NATIONAL UNIVERSITY LIBRARY. ALL RIGHTS RESERVED.
Certain data included herein are derived from the © Web of Science of Clarivate Analytics. All rights reserved.
You may not copy or re-distribute this material in whole or in part without the prior written consent of Clarivate Analytics.