Cited 0 time in
Reduction of Zygomatic Arch Isolated Fracture Using Ultra Sound and Needle Marking Background:
| DC Field | Value | Language |
|---|---|---|
| dc.contributor.author | 김준식 | - |
| dc.contributor.author | 박영지 | - |
| dc.contributor.author | 이윤정 | - |
| dc.contributor.author | 김남균 | - |
| dc.contributor.author | 이경석 | - |
| dc.date.accessioned | 2022-12-26T20:46:12Z | - |
| dc.date.available | 2022-12-26T20:46:12Z | - |
| dc.date.issued | 2016 | - |
| dc.identifier.issn | 2287-1152 | - |
| dc.identifier.issn | 2287-5603 | - |
| dc.identifier.uri | https://scholarworks.gnu.ac.kr/handle/sw.gnu/16065 | - |
| dc.description.abstract | Background: Zygomatic arch is a bony arch constituting the lateral midface, which consists of 25% of all midface fractures. There are a number of ways to evaluate the extent of zygomatic arch fracture. Some authors have reported successful treatment outcomes using ultrasound (U/S). To add to the previous methods, we have considered ways to accurately display the location of the fracture line while using U/S with 23 gauge needle marking. We introduce our method, which provided satisfactory results for reduction using a portable U/S, and it can evaluate the fracture line simultaneously when reduction of an isolated zygomatic arch fracture is necessary, and needle marking, which can easily point out the fracture line on U/S. Methods: We studied 21 patients with an isolated zygomatic arch fracture who underwent closed reduction using U/S and needle marking between 2013 and 2015. Results: We achieved satisfactory results in all our cases with respect to reduction by using the Dingman elevator after performing a temporal approach incision, while confirming relative positioning between needle marking and zygomatic fracture at the same time, after insertion of a 23 gauge needle in the skin above the zygomatic arch fracture line parallel to it. Conclusion: We treated 21 patients with an isolated zygomatic arch fracture using U/ S and the needle marking method, which provided satisfactory results because the extent of reduction of the fracture could be evaluated in real-time during the operation and exposure to radiation was reduced. | - |
| dc.format.extent | 4 | - |
| dc.language | 영어 | - |
| dc.language.iso | ENG | - |
| dc.publisher | 대한두개안면성형외과학회 | - |
| dc.title | Reduction of Zygomatic Arch Isolated Fracture Using Ultra Sound and Needle Marking Background: | - |
| dc.title.alternative | Reduction of Zygomatic Arch Isolated Fracture Using Ultra Sound and Needle Marking Background: | - |
| dc.type | Article | - |
| dc.publisher.location | 대한민국 | - |
| dc.identifier.bibliographicCitation | Archives of Craniofacial Surgery, v.17, no.4, pp 198 - 201 | - |
| dc.citation.title | Archives of Craniofacial Surgery | - |
| dc.citation.volume | 17 | - |
| dc.citation.number | 4 | - |
| dc.citation.startPage | 198 | - |
| dc.citation.endPage | 201 | - |
| dc.identifier.kciid | ART002174064 | - |
| dc.description.isOpenAccess | N | - |
| dc.description.journalRegisteredClass | kciCandi | - |
| dc.subject.keywordAuthor | Zygomatic fractures | - |
| dc.subject.keywordAuthor | Facial bones | - |
| dc.subject.keywordAuthor | Needles | - |
Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.
Gyeongsang National University Central Library, 501, Jinju-daero, Jinju-si, Gyeongsangnam-do, 52828, Republic of Korea+82-55-772-0532
COPYRIGHT 2022 GYEONGSANG NATIONAL UNIVERSITY LIBRARY. ALL RIGHTS RESERVED.
Certain data included herein are derived from the © Web of Science of Clarivate Analytics. All rights reserved.
You may not copy or re-distribute this material in whole or in part without the prior written consent of Clarivate Analytics.
