| dc.description.abstract | In this study, field experiment, odor simulator, and dispersion modeling were used to evaluate the odor impact from J sewage sludge treatment facility. The height and flow rate of exhaust stack at this facility were 22.3 m and 100 Nm3/min. The mean odor concentrations of the wet scrubber inlet and exhaust stack were 267±160 and 93±44 OU/m3, respectively. The odor removal efficiency of wet scrubber showed 65%. The odor simulator is used for the regulated standard calculation of the exhaust pipe(stack). Resulting odor emission rate(OER) by odor simulator was 2.4×106(24,000 OU/m3). The forecasting result by Screen3 modeling showed that odor exhaust concentration up to 30,000 OU/m3 was’t exceeded maximum allowable emission level on site boundary(15 OU/m3). | - |
| dc.format.extent | 7 | - |
| dc.language | 한국어 | - |
| dc.language.iso | KOR | - |
| dc.publisher | 한국환경과학회 | - |
| dc.title | 악취 배출구의 합리적인 배출규제를 위한 사례연구 | - |
| dc.title.alternative | A Case Study for Reasonable Emission Regulation of Odor Exhaust Stack | - |
| dc.type | Article | - |
| dc.publisher.location | 대한민국 | - |
| dc.identifier.doi | 10.5322/JESI.2016.25.1.155 | - |
| dc.identifier.bibliographicCitation | 한국환경과학회지, v.25, no.1, pp 155 - 161 | - |
| dc.citation.title | 한국환경과학회지 | - |
| dc.citation.volume | 25 | - |
| dc.citation.number | 1 | - |
| dc.citation.startPage | 155 | - |
| dc.citation.endPage | 161 | - |
| dc.identifier.kciid | ART002076244 | - |
| dc.description.isOpenAccess | Y | - |
| dc.description.journalRegisteredClass | kci | - |
| dc.subject.keywordAuthor | Odor exhaust stack | - |
| dc.subject.keywordAuthor | Emission regulation | - |
| dc.subject.keywordAuthor | Odor simulator | - |
| dc.subject.keywordAuthor | Screen3 model | - |
Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.
Gyeongsang National University Central Library, 501, Jinju-daero, Jinju-si, Gyeongsangnam-do, 52828, Republic of Korea+82-55-772-0532
COPYRIGHT 2022 GYEONGSANG NATIONAL UNIVERSITY LIBRARY. ALL RIGHTS RESERVED.
Certain data included herein are derived from the © Web of Science of Clarivate Analytics. All rights reserved.
You may not copy or re-distribute this material in whole or in part without the prior written consent of Clarivate Analytics.