dc.description.abstractThe purpose of this study is to analyze the design factors relating airborne infection in emergency rooms and find the required improvements. The architectural features in the main areas such as triage area, general treatment area, examine or testing area and waiting area are investigated in seven selected emergency rooms. As results, at first, triage area, general treatment area which seem to be open plan space are most likely weak in the respect of airborne infection, expecially in small emergency rooms. Secondly, the insufficient clearance between beds causes transmission of droplet nuclei and increase airborne infection risk. Consequently, physical separation between spaces or appropriate clearance between beds are suggested. If the physical separation is impossible, airflow control is required to prevent dispersion of droplet nuclei.-
dc.format.extent10-
dc.language한국어-
dc.language.isoKOR-
dc.publisher한국생활환경학회-
dc.title설계사례 조사를 통한 응급실 내 공기전파감염방지 개선방안-
dc.title.alternativeImprovement of Airborne Infection Prevention Methods in Emergency Room by Design Case Study-
dc.typeArticle-
dc.publisher.location대한민국-
dc.identifier.doi10.21086/ksles.2016.03.23.3.433-
dc.identifier.bibliographicCitation한국생활환경학회지, v.23, no.3, pp 433 - 442-
dc.citation.title한국생활환경학회지-
dc.citation.volume23-
dc.citation.number3-
dc.citation.startPage433-
dc.citation.endPage442-
dc.identifier.kciidART002123795-
dc.description.isOpenAccessN-
dc.description.journalRegisteredClasskci-
dc.subject.keywordAuthorEmergency room-
dc.subject.keywordAuthorPlan design-
dc.subject.keywordAuthorAirborne infection-
dc.subject.keywordAuthorDesign factors-
Files in This Item
There are no files associated with this item.
Appears in
Collections
공과대학 > Department of Architecture > Journal Articles
간호대학 > Department of Nursing > Journal Articles
공과대학 > School of Architectural Engineering > Journal Articles

qrcode

Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.

Related Researcher

Researcher Cheong, Chang Heon photo

Cheong, Chang Heon
공과대학 (건축공학부)
Read more

Altmetrics

Total Views & Downloads

BROWSE