The suprasternal notch as a landmark of chest compression depth in CPR

Authors
Kim, Tae HuLee, Soo HoonKim, Dong HoonLee, Ryun KyungKim, So YeonKang, ChangwooJeong, Jin HeeKim, Seong ChunLee, Sang Bong
Issue Date
Mar-2016
Publisher
W B SAUNDERS CO-ELSEVIER INC
Citation
AMERICAN JOURNAL OF EMERGENCY MEDICINE, v.34, no.3, pp 433 - 436
Pages
4
Indexed
SCIE
SCOPUS
Journal Title
AMERICAN JOURNAL OF EMERGENCY MEDICINE
Volume
34
Number
3
Start Page
433
End Page
436
URI
https://scholarworks.gnu.ac.kr/handle/sw.gnu/15649
DOI
10.1016/j.ajem.2015.11.026
ISSN
0735-6757
1532-8171
Abstract
Objective: This study was performed to determine a landmark for chest compression depth for adult cardiopulmonary resuscitation (CPR) using chest computed tomography and to evaluate the validity of the landmark. Methods: The external anteroposterior diameters (EAPDs) of each chest at the suprasternal notch (SN) and the lower half (LH) of the sternum were measured. We analyzed the differences in the EAPDs between the LH and the SN in each EAPD group in the LH of the sternum as follows: less than 20.00, 20.00 to 21.99, 22.00 to 23.99, greater than or equal to 24.00. We compared the differences in the EAPDs between the 2 points with 50 mm and the chest compression depth on simulated one-fourth external chest compressions for each EAPD group on the LH of the sternum. Results: The mean difference in the EAPDs between the SN and the LH was 5.16 +/- 0.91 mm. The differences in the EAPDs between the SN and the LH of the sternum with 50 mm did not indicate a significant difference. The mean one-fourth EAPD at the LH of the sternum was 5.50 +/- 0.53 mm. There was not a significant difference in the residual chest depth on one-fourth simulated chest compression for each EAPD group on the LH of the sternum. Conclusions: The SN may have value as a functional landmark for chest compression depth in adult CPR. Our findings combined with the simulated one-fourth chest compressions were more consistent with the depth between 50 and 60 mm recommended by the 2015 CPR guidelines. (C) 2015 Elsevier Inc. All rights reserved.
Files in This Item
There are no files associated with this item.
Appears in
Collections
College of Medicine > Department of Medicine > Journal Articles

qrcode

Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.

Altmetrics

Total Views & Downloads

BROWSE