Evaluation of the Diagnostic Accuracy of Nasal Cavity and Nasopharyngeal Swab Specimens for SARS-CoV-2 Detection via Rapid Antigen Test According to Specimen Collection Timing and Viral Load
DC Field | Value | Language |
---|---|---|
dc.contributor.author | Lee, Seungjun | - |
dc.contributor.author | Widyasari, Kristin | - |
dc.contributor.author | Yang, Hye-Ryun | - |
dc.contributor.author | Jang, Jieun | - |
dc.contributor.author | Kang, Taejoon | - |
dc.contributor.author | Kim, Sunjoo | - |
dc.date.accessioned | 2022-12-26T07:21:10Z | - |
dc.date.available | 2022-12-26T07:21:10Z | - |
dc.date.issued | 2022-03 | - |
dc.identifier.issn | 2075-4418 | - |
dc.identifier.issn | 2075-4418 | - |
dc.identifier.uri | https://scholarworks.gnu.ac.kr/handle/sw.gnu/1560 | - |
dc.description.abstract | The rapid diagnosis of SARS-CoV-2 is an essential aspect in the detection and control of the spread of COVID-19. We evaluated the accuracy of the rapid antigen test (RAT) using samples from the nasal cavity and nasopharynx based on sample collection timing and viral load. We enrolled 175 patients, of which 71 patients and 104 patients had tested positive and negative, respectively, based on real time-PCR. Nasal cavity and nasopharyngeal swab samples were tested using STANDARD Q COVID-19 Ag tests (Q Ag, SD Biosensor, Korea). The sensitivity of the Q Ag test was 77.5% (95% confidence interval [CI], 67.8-87.2%) for the nasal cavity and 81.7% (95% [CI, 72.7-90.7%) for the nasopharyngeal specimens. The RAT results showed a substantial agreement between the nasal cavity and nasopharyngeal specimens (Cohen's kappa index = 0.78). The sensitivity of the RAT for nasal cavity specimens exceeded 89% for <5 days after symptom onset (DSO) and 86% for Ct of E and RdRp < 25. The Q Ag test performed fairly well, especially in the early DSO when a high viral load was present, and the nasal cavity swab can be considered an alternative site for the rapid diagnosis of COVID-19. | - |
dc.language | 영어 | - |
dc.language.iso | ENG | - |
dc.publisher | MDPI | - |
dc.title | Evaluation of the Diagnostic Accuracy of Nasal Cavity and Nasopharyngeal Swab Specimens for SARS-CoV-2 Detection via Rapid Antigen Test According to Specimen Collection Timing and Viral Load | - |
dc.type | Article | - |
dc.publisher.location | 스위스 | - |
dc.identifier.doi | 10.3390/diagnostics12030710 | - |
dc.identifier.scopusid | 2-s2.0-85127450178 | - |
dc.identifier.wosid | 000776916000001 | - |
dc.identifier.bibliographicCitation | DIAGNOSTICS, v.12, no.3 | - |
dc.citation.title | DIAGNOSTICS | - |
dc.citation.volume | 12 | - |
dc.citation.number | 3 | - |
dc.type.docType | Article | - |
dc.description.isOpenAccess | Y | - |
dc.description.journalRegisteredClass | scie | - |
dc.description.journalRegisteredClass | scopus | - |
dc.relation.journalResearchArea | General & Internal Medicine | - |
dc.relation.journalWebOfScienceCategory | Medicine, General & Internal | - |
dc.subject.keywordPlus | CLINICAL-EVALUATION | - |
dc.subject.keywordPlus | COVID-19 | - |
dc.subject.keywordPlus | ASPIRATE | - |
dc.subject.keywordAuthor | SARS-CoV-2 | - |
dc.subject.keywordAuthor | COVID-19 testing | - |
dc.subject.keywordAuthor | rapid antigen test | - |
dc.subject.keywordAuthor | nasal cavity | - |
dc.subject.keywordAuthor | detection | - |
Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.
Gyeongsang National University Central Library, 501, Jinju-daero, Jinju-si, Gyeongsangnam-do, 52828, Republic of Korea+82-55-772-0533
COPYRIGHT 2022 GYEONGSANG NATIONAL UNIVERSITY LIBRARY. ALL RIGHTS RESERVED.
Certain data included herein are derived from the © Web of Science of Clarivate Analytics. All rights reserved.
You may not copy or re-distribute this material in whole or in part without the prior written consent of Clarivate Analytics.