dc.description.abstractWith the improvement of living standards, the ventilation for the mitigation of indoor or outdoor air-pollution problems has recently attracted a lot of attention. Consequently, the ventilation for the supply of outdoor fresh air into a room is treated as an important building-design factor. The ventilation is generally divided into the forced and natural types; here, the former can control the ventilation rate by using mechanical devices, but it has the disadvantages of the equipment costs, maintenance costs, and noise generation, while the latter is applied to most workshops due to the absence of noise and the low installation and maintenance costs. In this experimental study, the ventilation performance of a typical rotating-type natural ventilator, which is called a “wind turbine,” was investigated with the outdoor-wind velocity and the indoor/outdoor-temperature difference. From the experiment results, it was confirmed that the temperature difference of 10℃ corresponds to the ventilation driving force with an outdoor-wind velocity of 1.0 m/s. Additionally, the intake-opening area of a building also exerts a great effect on the ventilation rates.-
dc.format.extent10-
dc.language한국어-
dc.language.isoKOR-
dc.publisher대한설비공학회-
dc.title윈드터빈 자연환기 장치의 외기풍속 및 온도차에 따른 환기특성에 관한 실험연구-
dc.title.alternativeAn Experimental Study on the Ventilation Characteristics of a Wind-Turbine Natural Ventilator According to the Outdoor-Wind Velocity and the Indoor/Outdoor-Temperature Difference-
dc.typeArticle-
dc.publisher.location대한민국-
dc.identifier.doi10.6110/KJACR.2017.29.4.175-
dc.identifier.bibliographicCitation설비공학 논문집, v.29, no.4, pp 175 - 184-
dc.citation.title설비공학 논문집-
dc.citation.volume29-
dc.citation.number4-
dc.citation.startPage175-
dc.citation.endPage184-
dc.identifier.kciidART002214049-
dc.description.isOpenAccessN-
dc.description.journalRegisteredClasskci-
dc.subject.keywordAuthor차압-
dc.subject.keywordAuthor자연환기-
dc.subject.keywordAuthor온도차-
dc.subject.keywordAuthor환기구동력-
dc.subject.keywordAuthor풍속-
dc.subject.keywordAuthorDifferential Pressure-
dc.subject.keywordAuthorNatural Ventilation-
dc.subject.keywordAuthorTemperature Difference-
dc.subject.keywordAuthorVentilation Driving Force-
dc.subject.keywordAuthorWind Velocity-