Cited 0 time in
Investigation on the Reduction Effect on Cooling Power Consumption and Operating Cost of Mist-spray Outdoor Units in Air Conditioner
| DC Field | Value | Language |
|---|---|---|
| dc.contributor.author | 이건호 | - |
| dc.contributor.author | 조동우 | - |
| dc.contributor.author | 김혜미 | - |
| dc.contributor.author | 송영학 | - |
| dc.date.accessioned | 2022-12-26T19:16:13Z | - |
| dc.date.available | 2022-12-26T19:16:13Z | - |
| dc.date.issued | 2017 | - |
| dc.identifier.issn | 1229-6163 | - |
| dc.identifier.issn | 2383-5575 | - |
| dc.identifier.uri | https://scholarworks.gnu.ac.kr/handle/sw.gnu/14273 | - |
| dc.description.abstract | The use of the air conditioner is increasing due to the rise of the outdoor temperature during summer, and the problems of the fire and the cooling performance deterioration are caused due to lack of maintenance of the outdoor unit. In particular, overall performance of cooling system and efficiency in outdoor units have been degraded due to an intake of high-temperature outdoor air thereby increasing cooling energy and operating cost. Thus, this study aimed to increase efficiency of outdoor units by evaporating and cooling intake air through mist spray at the intake port surface in the outdoor unit. The measurements results showed that total power consumption of misting outdoor unit compared to that of conventional outdoor units was reduced by 21% approximately, and total power consumption of the entire system including pump was reduced by 16.7%. In addition, the operating cost including water use was reduced by 13.5% approximately. In summary, if a mist-spray nozzle kit is installed in air-cooled outdoor units, the reduction in the usage of cooling energy and operating cost will be achieved without replacement of existing cooling systems or a large scale of repairs. | - |
| dc.format.extent | 8 | - |
| dc.language | 영어 | - |
| dc.language.iso | ENG | - |
| dc.publisher | 대한건축학회 | - |
| dc.title | Investigation on the Reduction Effect on Cooling Power Consumption and Operating Cost of Mist-spray Outdoor Units in Air Conditioner | - |
| dc.title.alternative | Investigation on the Reduction Effect on Cooling Power Consumption and Operating Cost of Mist-spray Outdoor Units in Air Conditioner | - |
| dc.type | Article | - |
| dc.publisher.location | 대한민국 | - |
| dc.identifier.doi | 10.5659/AIKAR.2017.19.4.101 | - |
| dc.identifier.bibliographicCitation | Architectural Research, v.19, no.4, pp 101 - 108 | - |
| dc.citation.title | Architectural Research | - |
| dc.citation.volume | 19 | - |
| dc.citation.number | 4 | - |
| dc.citation.startPage | 101 | - |
| dc.citation.endPage | 108 | - |
| dc.identifier.kciid | ART002297233 | - |
| dc.description.isOpenAccess | N | - |
| dc.description.journalRegisteredClass | kci | - |
| dc.subject.keywordAuthor | Mist Spray | - |
| dc.subject.keywordAuthor | Outdoor Unit | - |
| dc.subject.keywordAuthor | Evaporative Cooling | - |
| dc.subject.keywordAuthor | Operating Cost | - |
| dc.subject.keywordAuthor | Cooling Efficiency | - |
Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.
Gyeongsang National University Central Library, 501, Jinju-daero, Jinju-si, Gyeongsangnam-do, 52828, Republic of Korea+82-55-772-0532
COPYRIGHT 2022 GYEONGSANG NATIONAL UNIVERSITY LIBRARY. ALL RIGHTS RESERVED.
Certain data included herein are derived from the © Web of Science of Clarivate Analytics. All rights reserved.
You may not copy or re-distribute this material in whole or in part without the prior written consent of Clarivate Analytics.