Detailed Information

Cited 0 time in webofscience Cited 0 time in scopus
Metadata Downloads

PV시스템 적용 공동주택의 에너지 제로화를 위한 적정 건축-규모 검토

Full metadata record
DC Field Value Language
dc.contributor.author정창헌-
dc.date.accessioned2022-12-26T19:02:51Z-
dc.date.available2022-12-26T19:02:51Z-
dc.date.issued2017-
dc.identifier.issn1976-6483-
dc.identifier.issn2586-0666-
dc.identifier.urihttps://scholarworks.gnu.ac.kr/handle/sw.gnu/14121-
dc.description.abstractEnergy consumption in building sector in South Korea is about 20~30%. Thus, net zero energy building became a social issue to reduce national CO2 emission and meet the national trend of climate mitigation. This study evaluates the appropriate size of net zero energy apartment building. PV(Photovoltaic) system is considered as an applicable renewable energy source for apartment buildings. Total energy consumption including private and public use is considered as a baseline. Energy evaluating method for apartment by Korean building code is slightly modified to reflect energy consumption for public use. Annual electricity generation is evaluated by using RETScreen program. The efficiency of PV panel is 13.5%. The results show the PV system cannot afford meet the energy demand in baseline apartment building. PV system only can fully supply energy for a residential unit. The results indicate that the policy to generalize zero residential buildings of South Korea, may only works in detached house sector. In order to establish net zero energy apartment, advanced energy mix should be considered.-
dc.format.extent8-
dc.language한국어-
dc.language.isoKOR-
dc.publisher한국건축친환경설비학회-
dc.titlePV시스템 적용 공동주택의 에너지 제로화를 위한 적정 건축-규모 검토-
dc.title.alternativeAppropriate Size of a Net Zero-Energy Multi-Family Housing using PV system-
dc.typeArticle-
dc.publisher.location대한민국-
dc.identifier.bibliographicCitation한국건축친환경설비학회 논문집, v.11, no.2, pp 113 - 120-
dc.citation.title한국건축친환경설비학회 논문집-
dc.citation.volume11-
dc.citation.number2-
dc.citation.startPage113-
dc.citation.endPage120-
dc.identifier.kciidART002218023-
dc.description.isOpenAccessN-
dc.description.journalRegisteredClasskci-
dc.subject.keywordAuthor공동주택-
dc.subject.keywordAuthor에너지 소비량-
dc.subject.keywordAuthor넷제로에너지-
dc.subject.keywordAuthorPV패널-
dc.subject.keywordAuthorMulti-Family Housing-
dc.subject.keywordAuthorEnergy consumption-
dc.subject.keywordAuthorZet Zero-Energy-
dc.subject.keywordAuthorPV panel-
Files in This Item
There are no files associated with this item.
Appears in
Collections
공과대학 > School of Architectural Engineering > Journal Articles

qrcode

Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.

Related Researcher

Researcher Cheong, Chang Heon photo

Cheong, Chang Heon
공과대학 (건축공학부)
Read more

Altmetrics

Total Views & Downloads

BROWSE