Detailed Information

Cited 0 time in webofscience Cited 0 time in scopus
Metadata Downloads

FE-SEM/EDX 분석법을 이용한 석탄화력발전소에서 배출되는 입자상물질의 확인자 개발

Full metadata record
DC Field Value Language
dc.contributor.author박정호-
dc.date.accessioned2022-12-26T19:01:47Z-
dc.date.available2022-12-26T19:01:47Z-
dc.date.issued2017-
dc.identifier.issn1225-4517-
dc.identifier.issn2287-3503-
dc.identifier.urihttps://scholarworks.gnu.ac.kr/handle/sw.gnu/14010-
dc.description.abstractCoal-fired power plants emit various Particulate Matter(PM) at coal storage pile and ash landfill as well as the stack, and affect the surrounding environment. Field Emission Scanning Electron Microscopy and Energy Dispersive X-ray analyzer(FE-SEM/EDX) were used to develop identification factor and the physico-chemical analysis of PM emitted from a power plant. In this study, three samples of pulverized coal, bottom ash, and fly ash were analyzed. The pulverized coal was spherical particles in shape and the chemical composition of C-O-Si-Al and C/Si and C/Al ratios were 200~300 on average. The bottom ash was spherical or non-spherical particles in shape, chemical composition was O-C-Si-Al-Fe-Ca and C/Si and C/Al ratios were 4.3±4.6 and 8.8±10.0. The fly ash was spherical particles in shape, chemical composition was O-Si-Ai-C-Fe-Ca and C/Si and C/Al ratios were 0.5±0.2 and 0.8±0.5.-
dc.format.extent7-
dc.language한국어-
dc.language.isoKOR-
dc.publisher한국환경과학회-
dc.titleFE-SEM/EDX 분석법을 이용한 석탄화력발전소에서 배출되는 입자상물질의 확인자 개발-
dc.title.alternativeIdentification Factor Development of Particulate Matters Emitted from Coal-fired Power Plant by FE-SEM/EDX Analysis-
dc.typeArticle-
dc.publisher.location대한민국-
dc.identifier.doi10.5322/JESI.2017.26.12.1333-
dc.identifier.bibliographicCitation한국환경과학회지, v.26, no.12, pp 1333 - 1339-
dc.citation.title한국환경과학회지-
dc.citation.volume26-
dc.citation.number12-
dc.citation.startPage1333-
dc.citation.endPage1339-
dc.identifier.kciidART002294423-
dc.description.isOpenAccessN-
dc.description.journalRegisteredClasskci-
dc.subject.keywordAuthorCoal-fired power plant-
dc.subject.keywordAuthorFE-SEM/EDX analysis-
dc.subject.keywordAuthorIdentification factor-
Files in This Item
There are no files associated with this item.
Appears in
Collections
건설환경공과대학 > 환경공학과 > Journal Articles

qrcode

Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.

Related Researcher

Researcher Park, Jeong Ho photo

Park, Jeong Ho
건설환경공과대학 (환경공학과)
Read more

Altmetrics

Total Views & Downloads

BROWSE