Detailed Information

Cited 11 time in webofscience Cited 0 time in scopus
Metadata Downloads

An experimental study of partial admission losses with various blade tip clearances using a linear cascade

Full metadata record
DC Field Value Language
dc.contributor.authorCho, Soo Yong-
dc.contributor.authorCho, Chong-Hyun-
dc.contributor.authorChoi, Sang-Kyu-
dc.date.accessioned2022-12-26T18:48:53Z-
dc.date.available2022-12-26T18:48:53Z-
dc.date.issued2017-03-01-
dc.identifier.issn0360-5442-
dc.identifier.issn1873-6785-
dc.identifier.urihttps://scholarworks.gnu.ac.kr/handle/sw.gnu/13824-
dc.description.abstractTurbo-expanders have been used for energy conversion in many fields. They are sometimes operated in partial admission mode, depending on the stability of the energy source, such as solar energy or waste thermal energy, which can fluctuate depending on environmental or process condition. The ability to operate in partial admission can be advantageous because it allows continuous operation without interchanging components. However, this method also leads to lower turbo-expander efficiency. This experimental study was conducted to investigate losses at various partial admission rates. In addition, the effect of tip clearance was studied since it is another important parameter affecting turbo-expander performance. A linear cascade was fabricated with a nozzle that was set to 65 based on the axial direction. A blade row was designed to be movable along the pitchwise direction in order to investigate flow characteristics as a function of blade movement. Flow structures and pressure losses were measured for various partial admission rates and tip clearances. The experiment was conducted at a Reynolds number of 3 x 10(5) based on the chord. The experimental results showed that losses in the passages depended not only on partial admission rate but also location relative to the nozzle. (C) 2017 Elsevier Ltd. All rights reserved.-
dc.format.extent11-
dc.language영어-
dc.language.isoENG-
dc.publisherPERGAMON-ELSEVIER SCIENCE LTD-
dc.titleAn experimental study of partial admission losses with various blade tip clearances using a linear cascade-
dc.typeArticle-
dc.publisher.location영국-
dc.identifier.doi10.1016/j.energy.2017.01.133-
dc.identifier.wosid000399267100053-
dc.identifier.bibliographicCitationENERGY, v.122, pp 627 - 637-
dc.citation.titleENERGY-
dc.citation.volume122-
dc.citation.startPage627-
dc.citation.endPage637-
dc.type.docTypeArticle-
dc.description.isOpenAccessN-
dc.description.journalRegisteredClasssci-
dc.description.journalRegisteredClassscie-
dc.description.journalRegisteredClassscopus-
dc.relation.journalResearchAreaThermodynamics-
dc.relation.journalResearchAreaEnergy & Fuels-
dc.relation.journalWebOfScienceCategoryThermodynamics-
dc.relation.journalWebOfScienceCategoryEnergy & Fuels-
dc.subject.keywordPlusPERFORMANCE-
dc.subject.keywordAuthorEnergy conversion-
dc.subject.keywordAuthorTurbo-expander-
dc.subject.keywordAuthorPartial admission-
dc.subject.keywordAuthorLinear cascade-
dc.subject.keywordAuthorExperiment-
Files in This Item
There are no files associated with this item.
Appears in
Collections
공과대학 > Department of Aerospace and Software Engineering > Journal Articles

qrcode

Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.

Altmetrics

Total Views & Downloads

BROWSE