Detailed Information

Cited 0 time in webofscience Cited 0 time in scopus
Metadata Downloads

The Effect of Intraoperative Exophthalmometric Values on Enophthalmos Correction in Inferior Orbital Wall Reconstructionopen access

Authors
Choi, Yu-JinKim, Ji HyeHuh, Hyoun DoKim, Seong JaeSeo, Seong Wook
Issue Date
Jul-2017
Publisher
KOREAN OPHTHALMOLOGICAL SOC
Keywords
Enophthalmos; Exophthalmometer; Inferior orbital wall fracture; Intraoperative exophthalmometric values
Citation
JOURNAL OF THE KOREAN OPHTHALMOLOGICAL SOCIETY, v.58, no.7, pp 769 - 775
Pages
7
Indexed
KCI
Journal Title
JOURNAL OF THE KOREAN OPHTHALMOLOGICAL SOCIETY
Volume
58
Number
7
Start Page
769
End Page
775
URI
https://scholarworks.gnu.ac.kr/handle/sw.gnu/13639
DOI
10.3341/jkos.2017.58.7.769
ISSN
0378-6471
2092-9374
Abstract
Purpose: To measure the enophthalmos corrective effect after inferior orbital wall reconstruction, we compared preoperative and intraoperative exophthalmometric values with postoperative exophthalmometric values. Methods: From January 2014 to April 2016, 60 eyes of 60 patients who underwent surgery for inferior orbital wall fracture were included. In Group 1, the exophthalmometric value was measured before surgery, during the operation, and 6 months after surgery using the Naugle exophthalmometer. In Group 2, the value was measured before surgery and 6 months after surgery using the Hertel exophthalmometer. The thickness of implants was determined by preoperative exophthalmometric values and overcorrection of 0.5 mm was performed in Group 1 patients with relatively large fractures. Results: The mean age of the patients was 32.4 years in Group 1 and 34.3 years in Group 2. The mean duration between injury and surgery was 4.2 weeks in Group 1 and 2.3 weeks in Group 2. There was no statistically significant difference between preoperative exophthalmometric values in Group 1 (-1.78 +/- 0.31 mm) and Group 2 (-1.81 +/- 0.26 mm), but postoperative exophthalmometric values between Group 1 (-0.25 +/- 0.78 mm) and Group 2 (-0.53 +/- 0.46 mm) were statistically different (p = 0.034). Conclusions: The exophthalmometric values and wall fracture size are important factors for determining implant thickness of inferior orbital wall reconstruction. Intraoperative measurement of exophthalmometric values should be considered in inferior orbital wall reconstruction for enophthalmos correction.
Files in This Item
There are no files associated with this item.
Appears in
Collections
College of Medicine > Department of Medicine > Journal Articles

qrcode

Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.

Related Researcher

Researcher Seo, Seong Wook photo

Seo, Seong Wook
의과대학 (의학과)
Read more

Altmetrics

Total Views & Downloads

BROWSE