Detailed Information

Cited 0 time in webofscience Cited 0 time in scopus
Metadata Downloads

Iatrogenic common carotid artery rupture during neck surgery rescued using covered stent - A case report -

Full metadata record
DC Field Value Language
dc.contributor.author김지윤-
dc.contributor.author신일우-
dc.contributor.author김선민-
dc.contributor.author강세빈-
dc.contributor.author이수희-
dc.contributor.author박경언-
dc.contributor.author이헌근-
dc.contributor.author손주태-
dc.contributor.author정영균-
dc.date.accessioned2022-12-26T17:47:47Z-
dc.date.available2022-12-26T17:47:47Z-
dc.date.issued2018-
dc.identifier.issn1975-5171-
dc.identifier.issn2383-7977-
dc.identifier.urihttps://scholarworks.gnu.ac.kr/handle/sw.gnu/12664-
dc.description.abstractCarotid artery rupture during head and neck surgery is a catastrophic, life-threatening emergency. Although recent incidence has declined, it still occurs in many patients. Hemorrhage from the carotid artery is usually massive and uncontrollable. Fast, aggressive treatment to prevent hemodynamic instability is required. Even if patients survive this event, they may experience severe neurological sequelae. A ruptured carotid artery is usually controlled by direct compression and arterial ligation. However, apart from the inherent difficulty of operation, these traditional surgical treatments are associated with high morbidity and mortality. In the past two decades, endovascular management has become a mainstay of carotid rupture treatment. We report a case of successful recovery without any sequelae after cardiovascular collapse due to an unintentional common carotid artery (CCA) rupture during neck surgery. The exposed CCA was treated with a covered stent. In such a case, multidisciplinary cooperation is crucial.-
dc.format.extent6-
dc.language영어-
dc.language.isoENG-
dc.publisher대한마취통증의학회-
dc.titleIatrogenic common carotid artery rupture during neck surgery rescued using covered stent - A case report --
dc.title.alternativeIatrogenic common carotid artery rupture during neck surgery rescued using covered stent - A case report --
dc.typeArticle-
dc.publisher.location대한민국-
dc.identifier.doi10.17085/apm.2018.13.3.292-
dc.identifier.bibliographicCitationAnesthesia and Pain Medicine, v.13, no.3, pp 292 - 297-
dc.citation.titleAnesthesia and Pain Medicine-
dc.citation.volume13-
dc.citation.number3-
dc.citation.startPage292-
dc.citation.endPage297-
dc.identifier.kciidART002370898-
dc.description.isOpenAccessY-
dc.description.journalRegisteredClasskci-
dc.subject.keywordAuthorAnesthesia-
dc.subject.keywordAuthorCommon carotid artery-
dc.subject.keywordAuthorInterventional radiology-
dc.subject.keywordAuthorStents.-
Files in This Item
There are no files associated with this item.
Appears in
Collections
College of Medicine > Department of Medicine > Journal Articles

qrcode

Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.

Related Researcher

Researcher Shin, Il Woo photo

Shin, Il Woo
의과대학 (의학과)
Read more

Altmetrics

Total Views & Downloads

BROWSE