Cited 0 time in
A Study of Zero Energy Building Verification with Measuring and Model-based Simulation in Exhibition Building
| DC Field | Value | Language |
|---|---|---|
| dc.contributor.author | 하주완 | - |
| dc.contributor.author | 박경순 | - |
| dc.contributor.author | 김환용 | - |
| dc.contributor.author | 송영학 | - |
| dc.date.accessioned | 2022-12-26T17:47:08Z | - |
| dc.date.available | 2022-12-26T17:47:08Z | - |
| dc.date.issued | 2018 | - |
| dc.identifier.issn | 1229-6163 | - |
| dc.identifier.issn | 2383-5575 | - |
| dc.identifier.uri | https://scholarworks.gnu.ac.kr/handle/sw.gnu/12590 | - |
| dc.description.abstract | With the change in Earth’s ecosystems due to climate change, a number of studies on zero energy buildings have been conducted globally, due to the depletion of energy and resources. However, most studies have concentrated on residential and office buildings and the performance predictions were made only in the design phase. This study verifies the zero-energy performance in the operational phase by acquiring and analyzing data after the completion of an exhibition building. This building was a retention building, in which a renewable energy system using a passive house building envelope, solar photovoltaic power generation panels, as well as fuel cells were adopted to minimize the maintenance cost for future energy-zero operations. In addition, the energy performance of the building was predicted through prior simulations, and this was compared with actual measured values to evaluate the energy performance of the actual operational records quantitatively. The energy independence rate during the measurement period of the target building was 123% and the carbon reduction due to the energy production on the site was 408.07 tons. The carbon reduction exceeded the carbon emission (331.5 tons), which verified the carbon zero and zero-energy performances. | - |
| dc.format.extent | 10 | - |
| dc.language | 영어 | - |
| dc.language.iso | ENG | - |
| dc.publisher | 대한건축학회 | - |
| dc.title | A Study of Zero Energy Building Verification with Measuring and Model-based Simulation in Exhibition Building | - |
| dc.title.alternative | A Study of Zero Energy Building Verification with Measuring and Model-based Simulation in Exhibition Building | - |
| dc.type | Article | - |
| dc.publisher.location | 대한민국 | - |
| dc.identifier.bibliographicCitation | Architectural Research, v.20, no.3, pp 93 - 102 | - |
| dc.citation.title | Architectural Research | - |
| dc.citation.volume | 20 | - |
| dc.citation.number | 3 | - |
| dc.citation.startPage | 93 | - |
| dc.citation.endPage | 102 | - |
| dc.identifier.kciid | ART002390920 | - |
| dc.description.isOpenAccess | N | - |
| dc.description.journalRegisteredClass | kci | - |
| dc.subject.keywordAuthor | Zero Energy Building | - |
| dc.subject.keywordAuthor | Data Measuring | - |
| dc.subject.keywordAuthor | Simulation | - |
| dc.subject.keywordAuthor | Renewable Energy | - |
| dc.subject.keywordAuthor | Energy Independence Rate | - |
Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.
Gyeongsang National University Central Library, 501, Jinju-daero, Jinju-si, Gyeongsangnam-do, 52828, Republic of Korea+82-55-772-0532
COPYRIGHT 2022 GYEONGSANG NATIONAL UNIVERSITY LIBRARY. ALL RIGHTS RESERVED.
Certain data included herein are derived from the © Web of Science of Clarivate Analytics. All rights reserved.
You may not copy or re-distribute this material in whole or in part without the prior written consent of Clarivate Analytics.
