Cited 0 time in
총인슬러지의 1차 침전지 반송에 따른 하수처리장 고형물 제거특성 연구
| DC Field | Value | Language |
|---|---|---|
| dc.contributor.author | 김종오 | - |
| dc.contributor.author | 정동기 | - |
| dc.contributor.author | 권혜정 | - |
| dc.contributor.author | 황준석 | - |
| dc.date.accessioned | 2022-12-26T17:31:45Z | - |
| dc.date.available | 2022-12-26T17:31:45Z | - |
| dc.date.issued | 2018 | - |
| dc.identifier.issn | 1225-7192 | - |
| dc.identifier.issn | 2289-0076 | - |
| dc.identifier.uri | https://scholarworks.gnu.ac.kr/handle/sw.gnu/12267 | - |
| dc.description.abstract | In this study, the solids removal characteristics using T-P sludge generated from PACl coagulation were analyzed by laboratory scale and full scale experiment. As the amounts of T-P sludge injection into the raw sewage influent increased at the rate of 0, 1, 2, 3, 4 %, the suspended solids concentrations after 20 minutes setting test decreased to 210, 137, 91, 64, 43 mg/L, respectively. The filtration time required for dewatering test of the raw sewage influent decreased to 982, 728, 658, 581, 492 sec for 0, 1, 2, 3, 4% of T-P sludge injection, respectively. As the amounts of PACl coagulant into the effluent from final setting tank increased at 0, 10, 20, 30, 40 mg/L, the required filtration times for T-P sludge increased into 12.3, 41.7, 53.7, 67.2, 79.5 sec and the dewaterability of T-P sludge decreased. After T-P sludge returned into the primary settling tank on J-si sewage treatment plants, the effluent concentrations of COD, SS, T-N and T-P from primary settling tank into bioreactor decreased by 35.9, 27.9, 22.2, and 52.6% due to the coagulation effects of the T-P sludge. Finally, it was found that the return of T-P sludge into the primary settling tank could result into the sludge reduction having a lower water content of 3.03% p than in case of the only T-P sludge dehydration. | - |
| dc.format.extent | 8 | - |
| dc.language | 한국어 | - |
| dc.language.iso | KOR | - |
| dc.publisher | 한국수처리학회 | - |
| dc.title | 총인슬러지의 1차 침전지 반송에 따른 하수처리장 고형물 제거특성 연구 | - |
| dc.title.alternative | Evaluation of Solids Removal Characteristics on Sewage Treatment Plants Using T-P sludge Return into the Primary Settling Tank | - |
| dc.type | Article | - |
| dc.publisher.location | 대한민국 | - |
| dc.identifier.doi | 10.17640/KSWST.2018.26.6.73 | - |
| dc.identifier.bibliographicCitation | 한국수처리학회지, v.26, no.6, pp 73 - 80 | - |
| dc.citation.title | 한국수처리학회지 | - |
| dc.citation.volume | 26 | - |
| dc.citation.number | 6 | - |
| dc.citation.startPage | 73 | - |
| dc.citation.endPage | 80 | - |
| dc.identifier.kciid | ART002421375 | - |
| dc.description.isOpenAccess | N | - |
| dc.description.journalRegisteredClass | kci | - |
| dc.subject.keywordAuthor | Filtration time | - |
| dc.subject.keywordAuthor | PACl | - |
| dc.subject.keywordAuthor | Primary settling tank | - |
| dc.subject.keywordAuthor | Solids removal | - |
| dc.subject.keywordAuthor | T-P sludge injection | - |
Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.
Gyeongsang National University Central Library, 501, Jinju-daero, Jinju-si, Gyeongsangnam-do, 52828, Republic of Korea+82-55-772-0532
COPYRIGHT 2022 GYEONGSANG NATIONAL UNIVERSITY LIBRARY. ALL RIGHTS RESERVED.
Certain data included herein are derived from the © Web of Science of Clarivate Analytics. All rights reserved.
You may not copy or re-distribute this material in whole or in part without the prior written consent of Clarivate Analytics.
