Cited 0 time in
Characteristics of PM10, PM2.5 and PM2.5/PM10 Ratio in Air Monitoring Stations in Gyeongnam
| DC Field | Value | Language |
|---|---|---|
| dc.contributor.author | 박정호 | - |
| dc.contributor.author | 서정민 | - |
| dc.date.accessioned | 2022-12-26T17:19:09Z | - |
| dc.date.available | 2022-12-26T17:19:09Z | - |
| dc.date.issued | 2018 | - |
| dc.identifier.issn | 1225-4517 | - |
| dc.identifier.issn | 2287-3503 | - |
| dc.identifier.uri | https://scholarworks.gnu.ac.kr/handle/sw.gnu/12119 | - |
| dc.description.abstract | The characteristics of PM10, PM2.5 and Ratio(PM2.5/PM10) of 11 urban air monitoring stations in Gyeongnam were analyzed for the last 3 years(`15~`17). The average of the all stations was PM10 45 μg/㎥, PM2.5 24 μg/㎥ and Ratio 0.54, and annual reduction rates were PM10 -2.9%, PM2.5 –2.7% and Ratio –1.2%, respectively. The seasonal characteristics of PM10 were spring 54 μg/㎥ > winter 48 μg/㎥ > summer/autumn 40 μg/㎥, PM2.5 were spring/winter 26 μg/㎥ > summer 23 > autumn 22 μg/㎥ and Ratio were summer 0.56 > winter 0.55 > autumn 0.54 > spring 0.51, respectively. The hourly characteristics of PM10 were 11 μg/㎥ higher than 09:00~12:00 at 03:00~06:00, PM2.5 were 6 μg/㎥ higher than 09:00~12:00 at 17:00~18:00 and Ratio were 0.07 higher than 04:00~06:00 at 19:00. By site, the highest concentration of PM10 was YJ site 53 μg/㎥ and PM2.5 was HW site 28 μg/㎥. And Ratio at HD site showed the largest reduction from `15 0.62 to `17 0.52. | - |
| dc.format.extent | 7 | - |
| dc.language | 영어 | - |
| dc.language.iso | ENG | - |
| dc.publisher | 한국환경과학회 | - |
| dc.title | Characteristics of PM10, PM2.5 and PM2.5/PM10 Ratio in Air Monitoring Stations in Gyeongnam | - |
| dc.title.alternative | Characteristics of PM10, PM2.5 and PM2.5/PM10 Ratio in Air Monitoring Stations in Gyeongnam | - |
| dc.type | Article | - |
| dc.publisher.location | 대한민국 | - |
| dc.identifier.doi | 10.5322/JESI.2018.27.10.925 | - |
| dc.identifier.bibliographicCitation | 한국환경과학회지, v.27, no.10, pp 925 - 931 | - |
| dc.citation.title | 한국환경과학회지 | - |
| dc.citation.volume | 27 | - |
| dc.citation.number | 10 | - |
| dc.citation.startPage | 925 | - |
| dc.citation.endPage | 931 | - |
| dc.identifier.kciid | ART002399812 | - |
| dc.description.isOpenAccess | N | - |
| dc.description.journalRegisteredClass | kci | - |
| dc.subject.keywordAuthor | Gyeongnam air monitoring stations | - |
| dc.subject.keywordAuthor | PM10 | - |
| dc.subject.keywordAuthor | PM2.5 | - |
| dc.subject.keywordAuthor | PM2.5/PM10 | - |
Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.
Gyeongsang National University Central Library, 501, Jinju-daero, Jinju-si, Gyeongsangnam-do, 52828, Republic of Korea+82-55-772-0532
COPYRIGHT 2022 GYEONGSANG NATIONAL UNIVERSITY LIBRARY. ALL RIGHTS RESERVED.
Certain data included herein are derived from the © Web of Science of Clarivate Analytics. All rights reserved.
You may not copy or re-distribute this material in whole or in part without the prior written consent of Clarivate Analytics.
