Verification of Energy Reduction Effect through Control Optimization of Supply Air Temperature in VRF-OAP System
| DC Field | Value | Language |
|---|---|---|
| dc.contributor.author | Lee, Je Hyeon | - |
| dc.contributor.author | Yoon, Hyun Jin | - |
| dc.contributor.author | Im, Piljae | - |
| dc.contributor.author | Song, Young-hak | - |
| dc.date.accessioned | 2022-12-26T17:17:51Z | - |
| dc.date.available | 2022-12-26T17:17:51Z | - |
| dc.date.issued | 2018-01 | - |
| dc.identifier.issn | 1996-1073 | - |
| dc.identifier.uri | https://scholarworks.gnu.ac.kr/handle/sw.gnu/12002 | - |
| dc.description.abstract | This paper developed an algorithm that controls the supply air temperature in the variable refrigerant flow (VRF), outdoor air processing unit (OAP) system, according to indoor and outdoor temperature and humidity, and verified the effects after applying the algorithm to real buildings. The VRF-OAP system refers to a heating, ventilation, and air conditioning (HVAC) system to complement a ventilation function, which is not provided in the VRF system. It is a system that supplies air indoors by heat treatment of outdoor air through the OAP, as a number of indoor units and OAPs are connected to the outdoor unit in the VRF system simultaneously. This paper conducted experiments with regard to changes in efficiency and the cooling capabilities of each unit and system according to supply air temperature in the OAP using a multicalorimeter. Based on these results, an algorithm that controlled the temperature of the supply air in the OAP was developed considering indoor and outdoor temperatures and humidity. The algorithm was applied in the test building to verify the effects of energy reduction and the effects on indoor temperature and humidity. Loads were changed by adjusting the number of conditioned rooms to verify the effect of the algorithm according to various load conditions. In the field test results, the energy reduction effect was approximately 15-17% at a 100% load, and 4-20% at a 75% load. However, no significant effects were shown at a 50% load. The indoor temperature and humidity reached a comfortable level. | - |
| dc.language | 영어 | - |
| dc.language.iso | ENG | - |
| dc.publisher | MDPI AG | - |
| dc.title | Verification of Energy Reduction Effect through Control Optimization of Supply Air Temperature in VRF-OAP System | - |
| dc.type | Article | - |
| dc.publisher.location | 스위스 | - |
| dc.identifier.doi | 10.3390/en11010049 | - |
| dc.identifier.scopusid | 2-s2.0-85040603080 | - |
| dc.identifier.wosid | 000424397600049 | - |
| dc.identifier.bibliographicCitation | ENERGIES, v.11, no.1 | - |
| dc.citation.title | ENERGIES | - |
| dc.citation.volume | 11 | - |
| dc.citation.number | 1 | - |
| dc.type.docType | Article | - |
| dc.description.isOpenAccess | Y | - |
| dc.description.journalRegisteredClass | scie | - |
| dc.description.journalRegisteredClass | scopus | - |
| dc.relation.journalResearchArea | Energy & Fuels | - |
| dc.relation.journalWebOfScienceCategory | Energy & Fuels | - |
| dc.subject.keywordPlus | VARIABLE REFRIGERANT-FLOW | - |
| dc.subject.keywordPlus | PUMP DESICCANT SYSTEMS | - |
| dc.subject.keywordPlus | CONDITIONING SYSTEM | - |
| dc.subject.keywordPlus | COOLING CONDITIONS | - |
| dc.subject.keywordPlus | PROCESSING UNIT | - |
| dc.subject.keywordPlus | SIMULATION | - |
| dc.subject.keywordPlus | PERFORMANCE | - |
| dc.subject.keywordPlus | SAVINGS | - |
| dc.subject.keywordPlus | SEASON | - |
| dc.subject.keywordPlus | INTEGRATION | - |
| dc.subject.keywordAuthor | variable refrigerant system (VRF) | - |
| dc.subject.keywordAuthor | outdoor air processing unit (OAP) | - |
| dc.subject.keywordAuthor | control algorithm | - |
| dc.subject.keywordAuthor | experiment | - |
| dc.subject.keywordAuthor | field test | - |
| dc.subject.keywordAuthor | energy savings | - |
Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.
Gyeongsang National University Central Library, 501, Jinju-daero, Jinju-si, Gyeongsangnam-do, 52828, Republic of Korea+82-55-772-0532
COPYRIGHT 2022 GYEONGSANG NATIONAL UNIVERSITY LIBRARY. ALL RIGHTS RESERVED.
Certain data included herein are derived from the © Web of Science of Clarivate Analytics. All rights reserved.
You may not copy or re-distribute this material in whole or in part without the prior written consent of Clarivate Analytics.