Study on Variation of Internal Heat Gain in Office Buildings by Chronology

Full metadata record
DC Field Value Language
dc.contributor.authorKim, Hyemi-
dc.contributor.authorPark, Kyung-Soon-
dc.contributor.authorKim, Hwan-Yong-
dc.contributor.authorSong, Young-Hak-
dc.date.accessioned2022-12-26T17:04:00Z-
dc.date.available2022-12-26T17:04:00Z-
dc.date.issued2018-04-
dc.identifier.issn1996-1073-
dc.identifier.issn1996-1073-
dc.identifier.urihttps://scholarworks.gnu.ac.kr/handle/sw.gnu/11764-
dc.description.abstractThe additional process of load calculation during the retrofit of heating, ventilation, and air conditioning (HVAC) equipment has been generally omitted in Korea, in recent years. Instead, a simple replacement of HVAC equipment, based on existing HVAC capacities, has been used, which is limited when taking the variation of internal heat gain into consideration, due to changes in the consumption power due to light and office automation (OA) equipment in recent years. Thus, this study aimed to identify a change in internal heat gains over 30 years, from 1985 to 2015, study investigated actual measurement-based academic papers and catalogs about OA equipment, lighting, and the number of occupants per unit area. The heat load produced from OA equipment has increased by approximately 49.6% in 2015 compared to that of 1980, and the heat load from lighting equipment has decreased by 47% compared to that of fluorescent-based lighting, and the heat load from human bodies was approximately 10 W/m(2) on average, which showed a minimal change over the past 30 years. The internal heat gain calculated for 30,000 m(2) of total floor area has increased constantly for the last 30 years. Note that the internal heat gains were designed excessively, as the values used in literature was approximately 17% to 50% smaller than the value used normally in the case of pre-2000 designs, and the values used after 2000 were approximately 35% to 50% smaller than the design standard value.-
dc.language영어-
dc.language.isoENG-
dc.publisherMDPI-
dc.titleStudy on Variation of Internal Heat Gain in Office Buildings by Chronology-
dc.typeArticle-
dc.publisher.location스위스-
dc.identifier.doi10.3390/en11041013-
dc.identifier.scopusid2-s2.0-85055184212-
dc.identifier.wosid000434703400324-
dc.identifier.bibliographicCitationENERGIES, v.11, no.4-
dc.citation.titleENERGIES-
dc.citation.volume11-
dc.citation.number4-
dc.type.docTypeArticle-
dc.description.isOpenAccessY-
dc.description.journalRegisteredClassscie-
dc.description.journalRegisteredClassscopus-
dc.relation.journalResearchAreaEnergy & Fuels-
dc.relation.journalWebOfScienceCategoryEnergy & Fuels-
dc.subject.keywordPlusENERGY-CONSUMPTION-
dc.subject.keywordPlusEQUIPMENT-
dc.subject.keywordAuthorinternal heat gain-
dc.subject.keywordAuthorOA load-
dc.subject.keywordAuthorlighting load-
dc.subject.keywordAuthoroccupancy load-
dc.subject.keywordAuthorplug load-
Files in This Item
There are no files associated with this item.
Appears in
Collections
공과대학 > School of Architectural Engineering > Journal Articles

qrcode

Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.

Related Researcher

Researcher Song, Young Hak photo

Song, Young Hak
공과대학 (건축공학부)
Read more

Altmetrics

Total Views & Downloads