Detailed Information

Cited 19 time in webofscience Cited 19 time in scopus
Metadata Downloads

Efficacy of 3D transoesophageal echocardiography for transcatheter device closure of atrial septal defect without balloon sizing

Full metadata record
DC Field Value Language
dc.contributor.authorJang, Jeong Yoon-
dc.contributor.authorHeo, Ran-
dc.contributor.authorCho, Min Soo-
dc.contributor.authorBae, Jaeseok-
dc.contributor.authorHong, Jung Ae-
dc.contributor.authorLee, Sahmin-
dc.contributor.authorAhn, Jung-Min-
dc.contributor.authorPark, Duk-Woo-
dc.contributor.authorKim, Dae-Hee-
dc.contributor.authorKang, Duk-Hyun-
dc.contributor.authorSong, Jae-Kwan-
dc.contributor.authorSong, Jong-Min-
dc.date.accessioned2022-12-26T17:01:31Z-
dc.date.available2022-12-26T17:01:31Z-
dc.date.issued2018-06-
dc.identifier.issn2047-2404-
dc.identifier.issn2047-2412-
dc.identifier.urihttps://scholarworks.gnu.ac.kr/handle/sw.gnu/11598-
dc.description.abstractAims Using balloon sizing to determine device size may cause complications and increase procedure time in performing transcatheter closure of atrial septal defect (ASD). We aimed to validate the clinical utility of a formula using measurements from 3D transoesophageal echocardiography (TOE) images in performing the procedure without balloon sizing. Methods and results We enrolled 248 consecutive patients with ASD in a prospective registry. In the first tier (n = 53), we determined the device size before the procedure using our formula and performed balloon sizing during the procedure to verify our decision. In the second tier (n = 195), the procedure was performed without balloon sizing. In the first tier, the estimated device size correlated well with the device size finally implanted (R = 0.961, P < 0.001; bias, 0.38 +/- 1.5 mm, P < 0.001) and with the stretched balloon diameter (R = 0.929, P < 0.001; bias, 0.13 +/- 2.0 mm, P < 0.001). In the second tier, the device size derived from the formula was used in all patients, with the exception of one patient who showed a deficient rim on the aorta and superior sides and ASD that was not on a single plane. Two patients with unfavourable morphologies for device implantation experienced embolization of the device. Of the 193 patients with procedural success (99.0%), 2 suffered from haemopericardium caused by atrial wall erosion by the device. There were no procedure-related deaths. Conclusion The transcatheter closure of ASD using the 3D TOE-derived formula without balloon sizing is clinically feasible and safe. However, caution should be taken to exclude unfavourable features of ASD (ClinicalTrials.gov number NCT 02097758).-
dc.format.extent6-
dc.language영어-
dc.language.isoENG-
dc.publisherOXFORD UNIV PRESS-
dc.titleEfficacy of 3D transoesophageal echocardiography for transcatheter device closure of atrial septal defect without balloon sizing-
dc.typeArticle-
dc.publisher.location영국-
dc.identifier.doi10.1093/ehjci/jex153-
dc.identifier.scopusid2-s2.0-85048155034-
dc.identifier.wosid000441150700017-
dc.identifier.bibliographicCitationEUROPEAN HEART JOURNAL-CARDIOVASCULAR IMAGING, v.19, no.6, pp 684 - 689-
dc.citation.titleEUROPEAN HEART JOURNAL-CARDIOVASCULAR IMAGING-
dc.citation.volume19-
dc.citation.number6-
dc.citation.startPage684-
dc.citation.endPage689-
dc.type.docTypeArticle-
dc.description.isOpenAccessY-
dc.description.journalRegisteredClasssci-
dc.description.journalRegisteredClassscie-
dc.description.journalRegisteredClassscopus-
dc.relation.journalResearchAreaCardiovascular System & Cardiology-
dc.relation.journalResearchAreaRadiology, Nuclear Medicine & Medical Imaging-
dc.relation.journalWebOfScienceCategoryCardiac & Cardiovascular Systems-
dc.relation.journalWebOfScienceCategoryRadiology, Nuclear Medicine & Medical Imaging-
dc.subject.keywordPlusPERCUTANEOUS CLOSURE-
dc.subject.keywordPlusOCCLUDER-
dc.subject.keywordPlusEROSION-
dc.subject.keywordPlusRECOMMENDATIONS-
dc.subject.keywordPlusCOMPLICATIONS-
dc.subject.keywordPlusSELECTION-
dc.subject.keywordPlusDIAMETER-
dc.subject.keywordPlusSAFETY-
dc.subject.keywordPlusSHAPE-
dc.subject.keywordPlusSIZE-
dc.subject.keywordAuthoratrial septal defect-
dc.subject.keywordAuthor3D echocardiography-
dc.subject.keywordAuthortranscatheter intervention-
Files in This Item
There are no files associated with this item.
Appears in
Collections
College of Medicine > Department of Medicine > Journal Articles

qrcode

Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.

Altmetrics

Total Views & Downloads

BROWSE