dc.description.abstractPurpose: The purpose of this study was to check the degree of residual microbial contamination after disinfection of reusable suction containers, used in an intensive care unit (ICU) and present basic data for efficient use through cost analysis in comparison to disposable suction containers. Method: This study was conducted on 32 reusable suction containers used in an ICU on a selected specific day. After disinfection and washing, specimens were collected from the used containers and cultured to check for microbial contamination. Additionally, a comparative narrative study analyzes the cost of using reusable suction containers and disposable suction containers. Data were analyzed with the SPSS WIN 20.0 program using real numbers and percentage χ2-test. Results: As a result of the study, microorganisms were found in all samples where in 30 were gram-positive (62.5%) while 13 were gram-negative (27.1%). Based on level of contamination, microorganisms were less than 10CFU/ml in 18 samples (56.3%); 11-99CFU/ml in six samples (18.8%); and more than 100CFU/ml in eight samples (25%). Cost per day for a reusable suction container was 10,655 + α while cost per day for a disposable suction container was 10,666 won. Conclusion: This study found that reusable suction containers, even after disinfection, accounted for factors of potential infection as well as microbial contamination. So, disposable suction containers are superior in cost-effectiveness and highly efficient for use with infected patients.-
dc.format.extent8-
dc.language한국어-
dc.language.isoKOR-
dc.publisher한국기초간호학회-
dc.title재상용 흡인 용기의 미생물 오염도 및 재사용 흡인 용기와 일회용 흡인 용기의 비용 분석-
dc.title.alternativeMicrobial contamination of reusable suction canister and cost analysis of reusable suction canister and disposable suction canister-
dc.typeArticle-
dc.publisher.location대한민국-
dc.identifier.doi10.7586/jkbns.2019.21.2.133-
dc.identifier.bibliographicCitationJournal of Korean Biological Nursing Science, v.21, no.2, pp 133 - 140-
dc.citation.titleJournal of Korean Biological Nursing Science-
dc.citation.volume21-
dc.citation.number2-
dc.citation.startPage133-
dc.citation.endPage140-
dc.identifier.kciidART002468803-
dc.description.isOpenAccessY-
dc.description.journalRegisteredClasskci-
dc.subject.keywordAuthor흡인-
dc.subject.keywordAuthor배액-
dc.subject.keywordAuthor중환자실-
dc.subject.keywordAuthor미생물 상호작용-
dc.subject.keywordAuthorSuction-
dc.subject.keywordAuthorDrainage-
dc.subject.keywordAuthorIntensive care unit-
dc.subject.keywordAuthorMicrobial interactions-
Files in This Item
There are no files associated with this item.
Appears in
Collections
간호대학 > Department of Nursing > Journal Articles

qrcode

Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.

Related Researcher

Researcher Jeon, Mi Yang photo

Jeon, Mi Yang
간호대학 (간호학과)
Read more

Altmetrics

Total Views & Downloads

BROWSE