Cited 0 time in
A study on the difference of gastrointestinal transit time with minimized capsule endoscope in dogs
| DC Field | Value | Language |
|---|---|---|
| dc.contributor.author | 이동환 | - |
| dc.contributor.author | 송중현 | - |
| dc.contributor.author | 유도현 | - |
| dc.contributor.author | 안수진 | - |
| dc.contributor.author | 이희천 | - |
| dc.contributor.author | 김용주 | - |
| dc.contributor.author | 한동현 | - |
| dc.contributor.author | 정동인 | - |
| dc.date.accessioned | 2022-12-26T15:47:00Z | - |
| dc.date.available | 2022-12-26T15:47:00Z | - |
| dc.date.issued | 2019 | - |
| dc.identifier.issn | 2508-1357 | - |
| dc.identifier.issn | 2508-139X | - |
| dc.identifier.uri | https://scholarworks.gnu.ac.kr/handle/sw.gnu/10198 | - |
| dc.description.abstract | This study compares the differences in the gastrointestinal transit time between the conventional capsule endoscope and a minimized capsule endoscope model in normal dogs to verify whether the minimization of capsule endoscope can help relief retention in the gastrointestinal tract, especially in the pyloric passage. Three male beagles were used as the experimental group for which the minimized capsule endoscope model was orally administered and the control group consisted of three beagle dogs for which the conventional capsule endoscope was orally administered. Nine experiments were conducted with three experiments for each dog in each group. The results showed a significant difference in the gastric transit time (GTT) by the minimization of the capsule endoscope between the two groups (control group: 123.3 ± 80 min, experimental group: 63.3 ± 40.9 min, p=0.019). In contrast, the difference in the small bowel transit time (SBTT) by the minimization of the capsule endoscope between the two groups (control group: 86.6 ± 58.9 min, experimental group: 80 ± 33.5 min, p=0.863) was not significant. In this study, the capsule endoscopes reached the large intestine without retention in the small intestine in all subjects. The significant difference in the GTT between the control group using the conventional capsule endoscope and the experimental group using the minimized capsule endoscope model suggests that the smaller size of the capsule endoscope is helpful in resolving retention in the gastrointestinal tract, thus shorting the GTT. | - |
| dc.format.extent | 6 | - |
| dc.language | 영어 | - |
| dc.language.iso | ENG | - |
| dc.publisher | 충북대학교 동물의학연구소 | - |
| dc.title | A study on the difference of gastrointestinal transit time with minimized capsule endoscope in dogs | - |
| dc.title.alternative | A study on the difference of gastrointestinal transit time with minimized capsule endoscope in dogs | - |
| dc.type | Article | - |
| dc.publisher.location | 대한민국 | - |
| dc.identifier.bibliographicCitation | Journal of Biomedical and Translational Research, v.20, no.3, pp 65 - 70 | - |
| dc.citation.title | Journal of Biomedical and Translational Research | - |
| dc.citation.volume | 20 | - |
| dc.citation.number | 3 | - |
| dc.citation.startPage | 65 | - |
| dc.citation.endPage | 70 | - |
| dc.identifier.kciid | ART002511186 | - |
| dc.description.isOpenAccess | N | - |
| dc.description.journalRegisteredClass | kci | - |
| dc.subject.keywordAuthor | capsule endoscopy | - |
| dc.subject.keywordAuthor | capsule retention | - |
| dc.subject.keywordAuthor | dog | - |
| dc.subject.keywordAuthor | gastrointestinal transit time | - |
| dc.subject.keywordAuthor | minimization | - |
Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.
Gyeongsang National University Central Library, 501, Jinju-daero, Jinju-si, Gyeongsangnam-do, 52828, Republic of Korea+82-55-772-0532
COPYRIGHT 2022 GYEONGSANG NATIONAL UNIVERSITY LIBRARY. ALL RIGHTS RESERVED.
Certain data included herein are derived from the © Web of Science of Clarivate Analytics. All rights reserved.
You may not copy or re-distribute this material in whole or in part without the prior written consent of Clarivate Analytics.